[HTML][HTML] Voltage imaging reveals the dynamic electrical signatures of human breast cancer cells
… All of the cancer cell lines exhibit a −VE rate significantly greater than that of the benign
MCF-10A breast epithelial line (p-values all ≤0.01. The p-values are for the comparison of the …
MCF-10A breast epithelial line (p-values all ≤0.01. The p-values are for the comparison of the …
Subcellular resolution three-dimensional light-field imaging with genetically encoded voltage indicators
… This section reproduces methods described by Quicke. We designed our LFM following the
principles set out by Levoy et al. We adapted a wide-field imaging system by placing an MLA …
principles set out by Levoy et al. We adapted a wide-field imaging system by placing an MLA …
Advances in two-photon scanning and scanless microscopy technologies for functional neural circuit imaging
Recent years have seen substantial developments in technology for imaging neural circuits,
raising the prospect of large-scale imaging studies of neural populations involved in …
raising the prospect of large-scale imaging studies of neural populations involved in …
[HTML][HTML] Single-neuron level one-photon voltage imaging with sparsely targeted genetically encoded voltage indicators
P Quicke, C Song, EJ McKimm… - Frontiers in cellular …, 2019 - frontiersin.org
… for a neuron at the origin due to other neurons at positions r i to be equal to 1 − P P T ~ …
P and P T correspond to the signal power from the target neuron and total measure power, …
P and P T correspond to the signal power from the target neuron and total measure power, …
3D localization for light-field microscopy via convolutional sparse coding on epipolar images
… Ui is the resulting light-field at the native image plane of a 4-f system and is formulated as the
inverted and stretched version of Uo(x, p). Φ(x) … found using Zh are often different from the p …
inverted and stretched version of Uo(x, p). Φ(x) … found using Zh are often different from the p …
Voltage-Sensitive Optical Probes for Measuring Cell Membrane Potentials: An Update and Applications to “Nonexcitable” Cells
Although membrane potentials (V m s) are fundamental to the functioning broadly of all cell
types, V m dynamics have mostly been studied in the so-called “excitable” cells (mainly …
types, V m dynamics have mostly been studied in the so-called “excitable” cells (mainly …
All-optical crosstalk-free manipulation and readout of Chronos-expressing neurons
All optical neurophysiology allows manipulation and readout of neural network activity with
single-cell spatial resolution and millisecond temporal resolution. Neurons can be made to …
single-cell spatial resolution and millisecond temporal resolution. Neurons can be made to …
[BOOK][B] The entangled relationship between Indigenous spatiality and government service delivery
SP Quicke - 2008 - research-repository.uwa.edu.au
The delivery of basic government services to remotely living and frequently mobile Indigenous
populations is a highly contentious issue; one which has recently received considerable …
populations is a highly contentious issue; one which has recently received considerable …
[PDF][PDF] Balancing the fluorescence imaging budget for all-optical neurophysiology experiments
The goal of this chapter is to establish a framework to evaluate imaging methodologies for
all-optical neurophysiology experiments. This is not an exhaustive review of fluorescent …
all-optical neurophysiology experiments. This is not an exhaustive review of fluorescent …
Model-inspired deep learning for light-field microscopy with application to neuron localization
Light-field microscopes are able to capture spatial and angular information of incident light
rays. This allows reconstructing 3D locations of neurons from a single snap-shot. In this work, …
rays. This allows reconstructing 3D locations of neurons from a single snap-shot. In this work, …