Abstract
Here, we establish a novel economic system to quantify C. elegans mechanosensory behavior and memory by a controllable nanoscale mechanical stimulation. Using piezoelectric sheet speaker, we can flexibly change the vibration properties at a nanoscale displacement level and quantify behavioral responses and memory under the control of each vibration property. This system will facilitate understanding of physiological aspects of C. elegans mechanosensory behavior and memory.
Introduction
Mechanical forces such as touch, vibration and gravity make vital influences on development and homeostasis of living organisms1,2. Animals cope with these stimuli by modifying behavior and thereby achieve physical interactions with environment3. The mechanism underlying mechanosensory behavior has been studied at various model organisms from bacteria and archaea to mammals4,5. However, physiological aspects of those behaviors, such as force and duration enough to sense, are not well understood.
Mechanosensory behavior in C. elegans is a traditional paradigm in which to examine mechanism underlying a response to mechanical forces6–8. Worms usually respond to nonlocalized vibrations such as the tapping of a cultivated Petri plate with a reversal escape response7. In addition, after spaced training for repeated mechanical tap stimulation, worms can habituate to the stimulus and exhibit a decrease in the magnitude of the withdrawal escape response. Therefore, worms can alter behavior based on their past experience9. Because the neural circuit underlying this behavior was completely determined, we can easily investigate neural and molecular mechanisms using C. elegans cell-specific genetic methods9,10. In general, the choice of technique to impose mechanical stimulation and to readout behavioral output is critical for understanding physiology of animal behavior. In C. elegans, mechanical stimulation has been provided by tapping only a single plate using a solenoid tapper11 or a ROBO cylinder10 or by the manual box-drop method9, in which a plastic box containing multiple Petri plates is manually dropped onto a hard surface from a constant height. However, in these methods, it has been difficult to precisely change the vibration properties such as frequency, amplitude and duration.
At a cellular level experiment, several mechanical stimulation methods have been established for the study of mechanotransduction12. These methods include mechano-clamp using piezo-driven system13,14, surface elongation of a flexible silicone elastomer15,16, and force application by magnetic particles17–19. In addition to these spatially confined methods, Nikukar et al. have recently reported an interesting method, “nanokicking”, using piezo actuator and demonstrated to evoke nanoscale nonlocalized vibration with high frequency (up to 1 kHz) across the entire surface of the Petri plates20,21. However, in this strategy, it was not demonstrated to evoke the frequency above 1 kHz. Furthermore, this method has not been applied to a living animal level experiment, particularly to it’s behavioral experiments.
In this study, we designed an economic nonlocalized vibration device using piezoelectric sheet speaker. This device allows for elaborately changing the vibration parameters and setting these parameters in a desired temporal pattern. Using this device, we clearly quantified reversal responses and memory of worms for nonlocalized vibration. Thus, our new device will facilitate understanding of physiological aspects C. elegans mechanosensory behavior by titrating vibration properties in the future.
We previously established the tap stimulation system using the cylinder and actuator, because this method was successfully applied to the quantification of tap habituation behavior in other groups10,11. In this system, amplitude of the nonlocalized vibration could be roughly changed, whereas its frequency and duration could not. Therefore, instead of the previous system, we used a piezoelectric speaker to evoke nonlocalized vibration on an agar surface of an NGM plate (Fig. 1 and 2A). The NGM plate on which worms were cultivated (Fig. 1A Step 1) was placed on a circular-shaped actuator of a piezoelectric speaker (Fig. 1A Step 2, and Fig. 2B-D). The actuator was connected to an amplifier (Fig. 2E). This device was also connected to an earphone jack of a desktop computer through an earphone splitter. The earphone splitter enables us to evoke nonlocalized vibration to multiple NGM plates at the same time.
Amplitude of vibration can be set by volume control of a computer, and this sound volume level was changed in the range of 0 to 100%. On the other hand, the free download software was used for setting the frequency and duration of the vibration. The frequency of vibration can be changed in the range of 0 to 5 kHz. The minimum duration of stimulation is 0.5 sec. Moreover, this devise potentially enables us to generate various waveforms such as sine wave, square wave, pulse wave and white noise.
Furthermore, semi-automation of training of worms was also needed for quantifying habituation memory due to its laborious protocol. The conventional training protocol consisted of five blocks of 20 mechanical stimuli (60 sec interstimulus interval) with a 1 hr rest period between each block22. To automatically train large populations of worms, we used a mouse macro system that enables us to program the automatic mouse cursor movement on the computer screen (Fig. 1A Step 3 and Supplementary Fig. 1). To accurately examine habituation memory of trained worms, we have simultaneously prepared untrained worms as a control.
We used laser interferometry to quantify mechanical stimuli evoked by our piezoelectric speaker system. We played 440 Hz sound (the standard tuning frequency) on a piezoelectric speaker and validated the vibration on the center of an agar surface in a Petri plate (Fig. 3A). Expectedly, as shown in Fig. Fig 3B, we succeeded in detecting 440 Hz frequency. Therefore, we have changed the vibration frequency on the center of agar surfaces using WaveGene (Fig. 3C). All the vibration frequencies determined by WaveGene (minimum frequency, 250 Hz) were clearly detected by the vibrometer. In addition, 80 Hz vibration was correctly detected by the accelerometer. These results indicate that our piezoelectric speaker system allows for evoking vibration with accurate frequency on the center of agar surface.
We have changed amplitude of vibration by volume control of computer. As shown in Fig. 3D, the amplitude quantified by vibrometer on an agar surface linearly increased as the sound volume level increased, and reached a plateau at 80% of the computer sound level. Importantly, we could detect 1 kHz vibrations with 10% and 20% of the computer sound level as the nanometer scale displacements. Therefore, we next changed the sound level in the range of 0 to 30% by 2% and quantified the displacement in each sound level (Fig. 3E). We could detect the 30.4 nm displacement in 2% of the sound level, and the displacement increased within a nanometer range as the sound volume level became higher. These results reveal that our economic piezoelectric speaker system allows for changing amplitude of vibration at a nanoscale resolution.
Then, we tried to measure 1 kHz vibration (50% of the computer sound level) evoked by WaveGene at the several positions on the agar surface (Fig. 3A and 3F). As a result, we detected almost no frequency deviations across the surface of the Petri plate. These results indicate that our piezoelectric speaker enables us to stimulate almost all worms under the same vibration properties, regardless of their positions on an agar surface.
We prepared both untrained and trained worms and quantified their mean reversal distances at 16 hrs after habituation training (Fig. 1A Step 4-5, Fig. 1B, Fig. 3). Untrained worms exhibited reversal responses to vibration with 1 kHz of frequency, 4.9 μm of amplitude (computer sound level, 100%) and 1 sec of duration (Fig. 3A and 3C). The mean (±SEM) reversal distance of these untrained worms (N = 110) in response to vibration was 1.82 mm (±0.10 mm) (Fig. 3C). On the other hand, in our previous tapping method, mean reversal distance of worms (N = 98) was 1.07 mm (±0.06 mm) (Fig. 3C), which was comparable with that reported in the other group’s paper11. Therefore, these quantifications have indicated that worms stimulated by our new system could exhibit longer reversal distances than those stimulated by the old tapping system.
We further examined habituation memory of trained worms (Fig. 3B). The mean reversal distance of the trained worms (N = 135) in response to vibration was 1.36 mm (±0.09 mm). This result revealed that worms trained by our new system showed significantly reduced reversal distance compared with untrained worms (Fig. 3C). Thus, our new system could clearly induce mechanosensory memory through habituation training.
In summary, our system allows for not only quantification of mechanosensory behavior but also training of worms and quantifications of their memory. One of the important advantages for the researcher is that the new system with a device to quantify stimulus is an economic setup (< approximately 130 dollars / a single vibration device) and easily replicated in other laboratories. In addition, we can easily change the vibration properties. Our behavioral experiments have proved the capability of this system. In addition, this system is so compact as to be integrated into another experimental device such as a calcium imaging system. Therefore, our new system will facilitate investigation of physiological aspects of behavior and neural circuitry in the future.
Online Methods
Strain preparation
We used wild-type N2 Bristol strain for all behavioral experiments. This strain has been maintained and handled using standard methods23.
Vibration device construction and it’s validation
To control properties of nonlocalized vibration precisely, a new system was constructed using the piezoelectric sheet speaker (THRIVE, pzBAZZ μSpeaker B35) as an actuator and the amplifier module (THRIVE, 0530AMPZ) connected to a computer earphone jack via an earphone splitter. The diameter of sheet speaker was 42 mm, and frequency could be increased at least up to 5 kHz. The amplitude could be also changed by volume control of the computer in the range of 0 to 100% (Dell PRECISION T1650 desktop computer). The minimum duration of vibration is 0.5 sec. The mechanical stimuli were quantified by laser vibrometer V100 (Denshigiken Corp.) with PicoScope oscilloscope.
Behavioral recording
All worms’ behaviors were recorded at > 7.0 frames / sec using USB-controlled CCD cameras (Sentech, STCTB83USB-AS), which were each coupled to a 25 mm focal-length C-mount machine vision lens (Azure, AZURE-2514MM) and C-mount adaptor (5 mm thickness, 30CMA-R). Each pixel in the captured images corresponds to a 25.4 μm × 25.4 μm area in each Petri plate. The total field captured was 26.0 mm × 19.5 mm.
Software
Two free download software were used for automatic stimulation; WaveGene Ver. 1.50 for control of vibration properties and mouse macro HiMacroEX 2.46 for automatic habituation instead of manual operation. The software was compiled and bench marked on a Dell PRECISION T1650 desktop computer (Dell). The script written in HiMacroEx 2.46 was indicated in the Supplementary Fig. 1.
The reversal distance was calculated according to a previously reported method10. At first, an acquired AVI format movie was transformed into Tiff-format sequential images using ImageJ software (NIH). This sequential image file was used for subsequent motion analysis of each worm. Image-processing software for the quantification of each worm’s reversal distance was written in Mathematica 9.0 (Wolfram). The coordinate of each worm at initial frame was extracted manually. Then, the centroid of each worm was calculated and a track was generated by matching centroid positions between sequential frames. This track was used to calculate reversal distance. Initially, reversal distance of each worm was calculated automatically by the software. After this initial calculation, a frame number in which reversal movement was completed was manually confirmed for each worm using output result. Then, correct frame numbers for worms that indicate incorrect frame numbers in the initial calculation was extracted manually and put into the software for recalculation of their reversal distances. The detail instruction for this software was described in the Supplemental file.
Habituation training
Worms were cultivated on 60 mm Petri plates (Thermo Fisher Scientific, #150288) containing 10 mL of NGM with 2% agar, on which Escherichia coli OP50 was seeded. On the first day, 8-9 worms were deposited onto each NGM plate and cultivated at 20 °C. After 3 hrs, the deposited P0 worms were removed to segregate the F1 progeny. The progeny were cultivated for 64 hrs at 20 °C. An NGM plate on which worms were cultivated was placed on an actuator of a piezoelectric sheet speaker and stimulated through WaveGene. The training protocol was flexibly customized using Mouse macro HiMacroEX 2.46. In this study, the conventional training22 was adopted for worms within a 20 °C incubator (ADVANTEC). The nonlocalized vibrations were evoked at every 1 min for 20 times, and this stimulation sequence was repeated five times with a 1 hr interval.
Acknowledgements
We thank Caenorhabditis Genetic Center for sharing strains. T.S. and R.I. were supported by the Japan Society for the promotion of Science, Japan Science and Technology Agency under Precursory Research for Embryonic Science and Technology (PRESTO). T.S. was supported by Mochida Memorial Foundation for Medical and Pharmaceutical Research.