Skip to main content
bioRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search
New Results

A microfluidic biodisplay

Francesca Volpetti, Ekaterina Petrova, Sebastian J. Maerkl
doi: https://doi.org/10.1101/112110
Francesca Volpetti
Institute of Bioengineering, School of Engineering, EcolePolytechniqueFederalede Lausanne
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ekaterina Petrova
Institute of Bioengineering, School of Engineering, EcolePolytechniqueFederalede Lausanne
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sebastian J. Maerkl
Institute of Bioengineering, School of Engineering, EcolePolytechniqueFederalede Lausanne
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: sebastian.maerkl@epfl.ch
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Supplementary material
  • Preview PDF
Loading

ABSTRACT

Synthetically engineered cells are powerful and potentially useful biosensors, but it remains difficult to deploy such systems due to practical difficulties and biosafety concerns. To overcome these hurdles, we developed a microfluidic device that serves as an interface between an engineered cellular system, environment, and user. We created a biodisplay consisting of 768 individually programmable biopixels and demonstrated that it can perform multiplexed, continuous environmental monitoring. The biodisplay detected 10 μg/l sodium-arsenite in tap water using a research grade fluorescent microscope, and reported arsenic contamination down to 20 μg/l with an easy to interpret “skull and crossbones” symbol detectable with a low-cost USB microscope or by eye. No chemical or biological material is released by the biodisplay preventing environmental contamination. The microfluidic biodisplay thus provides a practical solution for the deployment and application of engineered cellular systems.

INTRODUCTION

With the advent of synthetic biology, a number of biological sensors have been engineered capable of monitoring the environment1,2. Although such synthetic biological systems are in principle extremely powerful sensors and information processing units, they often lack direct applicability because suitable interfaces between the environment, the user and the engineered biological system don’t exist. The lack of such interfaces results in problems related to safely deploying genetically modified organisms (GMOs), while making it possible for them to interact with the environment and user. Aside from safety concerns, interfaces can solve practical problems such as keeping the engineered biological system alive for extended periods of time, automatic and frequent sampling of the environment, and facilitating readout.

Microfluidics originated as a tool to enable analytical measurements in chemistry and biology3. In the last decades, microfluidic devices have found a plethora of applications in biology spanning high-throughput screening, cell-based assays, and molecular diagnostics. The use of microfluidic devices increases throughput, reduces cost, and can enable novel measurements4. In most instances the purpose of microfluidics is to enable or conduct analytical measurements of molecules or cells. A few examples depart from this dogmatic application of microfluidics and instead employ microfluidic devices as soft robots capable of movement and camouflage5, or as microfluidic games6. One recent example demonstrated how engineered biological systems can be deployed by combining bacterial sensors with microfluidic channels in a wearable hydrogel-elastomer hybrid device capable of sensing and reporting the presence of DAPG, IPTG, AHL and Rham7.

We have previously developed a method to culture and interrogate 1 ’152 S. cerevisiae strains on a microfluidic device. Each strain is cultured in a dedicated micro-chemostat and is interrogated optically to provide single-cell, phenotypic information on each strain. We applied this platform to the comprehensive, single-cell analysis of yeast proteome dynamics8 and to the detailed characterization and modeling of transcriptional regulation9. Here we show that this approach can be used to generate a bacterial biodisplay. Unlike previous bacterial biodisplays10, each of the 768 pixels can be independently programmed with a specific bacterial strain or clone. Once programmed, the device cultures cells for extended periods of time, while preventing contamination of the environment by GMOs contained on the device. We used the biodisplay to characterize the response of several engineered bacterial strains to small molecule analytes.

To demonstrate environmental monitoring, we programmed the biodisplay with a “skull and crossbones” symbol using a bacterial arsenic sensor strain. The symbol is displayed when arsenic contaminated water is sensed by the biodisplay. We also demonstrate a multiplexed biodisplay that reports on the presence or absence of two small molecules: arabinose and arsenic. The use of an easy-to-interpret symbolic display drastically simplifies analysis, and is readily understood by a layman without any special hardware or analysis requirements. To enable field-deployment of our biodisplay we show that readout can be conducted using an off-the-shelf low-cost USB microscope, a cellphone, or direct visual inspection. Finally, to increase shelf-life and facilitate shipping / deployment of the biodisplay we programmed the device with B. subtilis spores, which allowed storage of the display at 80°C for 1 month without any detectable decrease in viability or sensing functionality.

RESULTS

Biodisplay programming, culturing, sampling and readout

The biodisplay has a resolution of 48×16 for a total of 768 programmable pixels with a density of 64 pixels per inch (PPI) (Fig. 1a). Each pixel consists of a 250 μm square cell chamber, two side channels for medium and sample introduction, sandwich valves to isolate adjacent pixels and a neck valve to isolate the pixel from the side channels. Each pixel of the biodisplay can be programmed with a different bacterial strain. Standard microarray spotting was used to array bacterial cells or spores on an epoxy-coated glass slide. E. coli was spotted in medium containing 10% glycerol to preserve cell viability, as we observed that dried E. coli spots failed to regrow after spotting. B. subtilis spores could be spotted in water without addition of glycerol. The bacterial array was then aligned to the microfluidic chip and bonded at 37°C for 1 hour.

Figure 1.
  • Download figure
  • Open in new tab
Figure 1.

Biodisplay schematic and use. (a) Design of the two-layer microfluidic device (control channels in blue and flow channels in green). The device is composed of 16 rows and 48 columns for a total of 768 biopixels. Each pixel consists of a spotting chamber (1), chamber valve (2), sandwich valves (3) and side channels (4). The side channels in turn can be specifically addressed using the side channel valves (5). A bacterial cell array is spotted on a glass slide and aligned with the PDMS chip. (b) The culturing sequence consists of 3 steps: i) flowing medium with the chambers closed (10 minutes), ii) incubation with the sandwich valves closed and chamber valves open (45 minutes), and iii) flowing lysis buffer with the chamber closed (10 minutes). (c) The sampling sequence consists of 4 steps: i) flowing the medium in both side channels (10 minutes), ii) flowing the sample in one side channel (10 minutes), iii) incubation with both medium and sample (45 minutes), and iv) flowing lysis buffer (10 minutes). The sequence is than repeated continuously for the extent of the experiment. (d) The biodisplay can be imaged using a standard research grade epi-fluorescent microscope, a USB fluorescent microscope, a cellphone camera, or by eye.

After assembling and bonding the biodisplay, cells were allowed to recover overnight using an automated culturing routine (Fig. 1b). A medium reservoir was attached to the device and the waste outlet was connected to a receptacle containing 70% aq. EtOH to immediately sterilize and contain the device outflow. First, the entire device was loaded with medium by outgas priming11. Once the device was fully primed with medium, cells were cultured with the following three-step culturing routine: i) flowing medium through the side channels (10 minutes), ii) allowing medium to diffuse into the biopixels (45 minutes) and iii) flowing lysis buffer through the side channels (10 minutes). Whenever fluid was flowed through the side channels, the biopixel chambers were sealed off from the side channels using a set of valves. In step (ii) the biopixel valves were opened to allow diffusion of molecules in and out of the biopixel chamber. During this step, individual pixels were isolated from one another by the sandwich valves. The lysis segment of the culturing routine prevented biofilm and microcolony formation outside of the biopixels12. By actively preventing accumulation and growth of cells in areas other than the biopixels we prevented device clogging and allowed experiments to proceed for several days; the longest experiment conducted here lasted one week. Culturing was performed at 37°C using a thermo glass plate (Okolab). Culturing at 37°C increases growth rate, leading to faster accumulation of biomass, but was otherwise not required and incubation at room temperature was also possible. After overnight culturing, each bacterial spot had outgrown, and populated its dedicated biopixel. We did not observe any contamination resulting from microarraying. Cells occasionally populated empty biopixels during culturing, which was avoided by spotting a non-fluorescent E. coli strain in otherwise empty biopixels.

Once the biodisplay was online, we switched from the culturing routine to a sampling routine that enables frequent testing of a liquid sample (Fig. 1c). The sampling routine was identical to the culturing routine, with an additional step added prior to diffusive mixing of the pixel and side channels. After flowing medium through both side channels, the sample was flowed through one of the side channels. During the diffusion step, both the medium and the sample were allowed to diffuse into the biopixel chambers. This process allowed us to aspirate a sample directly from an environmental source, rather than having to premix it manually with the medium solution. By using a dedicated sampling port, it was possible to sample a source for extended periods of time in 75 minute intervals without user interference.

We employed a standard research grade epi-fluorescent microscope (Nikon) and a handheld, low-cost USB fluorescent microscope (Dino-Lite) for device readout and quantitation (Fig. 1d). The standard epi-fluorescent microscope equipped with a motorized stage was programmed to image each biopixel individually whereas the handheld USB microscope could image either the entire display or acquire several sub-sections. Both approaches were used to acquire time course and endpoint measurements. We also demonstrated that the biodisplay could be observed directly by eye using a LED flashlight and an emission filter, and images could be acquired using a standard cellphone camera.

Multiplexed characterization of bacterial strains

We tested the biodisplay device by culturing and characterizing nine E. coli strains engineered to induce GFP or RFP expression in response to arabinose (Supplementary Table 1). These strains were obtained from the iGEM registry of standard biological parts and were generated by various student teams. The fluorescent protein genes were under the regulation of a pBAD promoter or derivatives thereof. We programmed the biodisplay with the nine strains, each strain filling 2 columns of the device for a total of 32 pixels per strain. Strains were induced with arabinose after overnight culturing at 37°C. Induction was performed at room temperature (Fig. 2a) or 37°C (Supplementary Fig. 1). Room temperature induction was used in order to assess the performance of the biodisplay and cell-based sensors at ambient temperature in order to reduce platform complexity by eliminating the need for a temperature control element.

Figure 2.
  • Download figure
  • Open in new tab
Figure 2.

Using the biodisplay for strain characterization. (a) Fluorescence kymograms of nine arabinose-sensing E. coli strains. Shown is a representative biopixel for each strain and condition tested. The strains were induced twice for 24 hours with 0.0074 mM, 0.074 mM, 0.74 mM and 7.4 mM arabinose. (b) Quantitative analysis of fluorescence pixel intensities for each strain under four arabinose concentrations. The yellow background denotes the two induction periods. Each data point represents the average of eight pixels with error bars representing to the std. deviation of the means.

We designed the biodisplay device so that it was possible to specifically address four sets of four rows with a different solution. We used this modality to characterize each strain against four arabinose concentrations: 0.0074 mM, 0.074 mM, 0.74 mM, 7.4 mM (0.0001%, 0.001%, 0.01% and 0.1% w/v) arabinose in LB medium. Altogether, we tested 36 strain – inducer combinations by measuring nine strains in response to four arabinose concentrations with eight technical repeats for each combination. The biodisplay was placed on an automated research-grade fluorescent microscope and imaged over time

We performed two consecutive 24 hour inductions, with the second induction starting 2.5 days after the end of the first (Fig. 2). Upon induction we observed a measurable signal in all strains. All three of the GFP strains showed a strong response to 7.4 mM arabinose while only strain #3 induced highly in response to 0.74 mM. Strains #1 and #2 induced to low levels in response to 0.74 mM and failed to induce to appreciable levels at lower arabinose concentrations, whereas strain #3 also induced in the presence of 0.074 mM arabinose. These results indicated that strains #2 and #3 could be used in combination to distinguish three different inducer concentrations ranging over 3 orders of magnitude. All RFP strains induced expression to differing degrees in response to 7.4 mM arabinose and in the cases of RFP strains #2-6 also to 0.74 mM arabinose. All strains, with the exception of strain GFP_1 slowly decreased in intensity during the 2.5 days de-induction period. Strain GFP_1 exhibited a transient expression profile with signal beginning to decrease during the induction phase. GFP_1 is also the only strain that failed to induce during the second induction when cultured at room temperature but induced well in the second induction when cultured at 37°C (Supplementary Fig. 1). The transient expression profile can be attributed to the DH5-α background used and the presence of a LVA protease tag which is not present in any of the other strains tested.

Using the same approach we tested nine engineered arsenic responsive bacterial strains13,14. We chose arsenic responsive strains, for use in a biodisplay for low-cost, continuous environmental arsenic monitoring. After overnight growth, we flowed LB medium with 0 μg/l, 10 μg/l, 100 μg/l and 500 μg/l sodium-arsenite for 24 hours and quantitated GFP expression over time. The experiment was performed at room temperature. Strain EDI_as_4 in particular showed high expression of GFP and detected sodiumarsenite down to 10 μg/l (Supplementary Fig. 2). We thus chose this strain for all further arsenic sensing applications.

This series of experiments demonstrated that our biodisplay is a viable high-throughput platform for longterm culturing and characterization of bacterial strains. Theoretically, up to 768 strains can be characterized in parallel on this platform under dynamically changing media conditions8, which is otherwise difficult to achieve using standard microplate batch cultures or low-throughput microfluidic devices.

Biodisplay

High levels of arsenic in groundwater are common in a number of countries including China, India, and the USA. Not only is arsenic a concern in water supplies, high arsenic levels have also been found in a number of food sources15, particularly rice16,17.In Bangladesh, an estimated 20 – 45 million people are affected by arsenic levels that exceed the national standard of 50 μg/l and the WHO / EPA standard of 10 μg/l18. Worldwide it is estimated that over 200 million people are exposed to unsafe arsenic levels of 10 μg/l or above19. Arsenic also tops the ATSDR substance priority list20, which lists those substances “determined to pose the most significant and potential threat to human health”. Our biodisplay could serve as a continuous environmental water monitor that is low-cost, readily deployable in resource limited settings, and easy to interpret.

We programmed our biodisplay with an arsenic sensing E. coli strain (EDI_as_4) spelling “As”, the elemental symbol for arsenic, and a “skull and crossbones” symbol commonly used to warn of toxic substances (Fig. 3a). All pixels not programmed with the arsenic sensing strain were programmed with a non-fluorescent strain to prevent invasion and cross-contamination by the arsenic sensing strain. After overnight growth, sodium-arsenite in tap water was sampled by the device using the sampling routine described above. The biodisplay was kept at room temperature for the entire duration of the sampling routine. Using the research grade fluorescent microscope for readout, the biodisplay detected as little as 10 μg/l sodium-arsenite, and 20 μg/l sodium-arsenite was detected with the handheld low-cost fluorescent USB microscope (Supplementary Fig. 3). Fluorescent signal and the appearance of the “As” and “skull and crossbones” symbols was detected after 10 hours by the research grade microscope (Supplementary Fig. 4). After 24 hours a strong fluorescent signal had developed that could be easily imaged with a low-cost handheld USB microscope. A negative control biodisplay, which was run under identical conditions but exposed to tap water without added arsenic showed no detectable fluorescent signal.

Figure 3
  • Download figure
  • Open in new tab
Figure 3

Figure 3 Biodisplay. (a) Arsenic-responsive E. coliwas spotted according to the indicated pattern, spelling “As” and forming a “skull and crossbones” symbol. 20 μg/l of sodium-arsenite in tap water was sampled and images were acquired using Nikon and USB microscopes after 24 hours. (b) Multiplexed detection of arabinose (blue) and arsenic (red) by two E. coli strains that were spotted to display a “smiley” and a “skull and crossbones” symbol, respectively. Nikon and USB images of the chip were acquired after flowing all combinations of 7.4 mM arabinose and 100 μg/l sodium-arsenite in tap water in four independent experiments. Scale bars: 750 μm (c) Quantitation of GFP intensity, after 24 hours of induction, measured using the USB microscope. (d). The device exposed to both arsenic and arabinose, was imaged using a mobile phone. The image was obtained using the illumination with blue LEDs and a band-pass filter, placed in front of the cellphone camera. Scale bar: 3.5 mm

Given the large number of programmable pixels and high pixel density on our biodisplay we explored the possibility of generating a biodisplay that could sense and report the presence or absence of multiple substances in a sample. We selected the same arsenic sensing strain as above and the iGEM GFP_3 strain for arabinose sensing. The arsenic sensing strain was spotted in the form of a “skull and crossbones” pattern whereas the arabinose sensing strain was spotted in a “smiley” pattern. We performed four separate experiments exposing a new biodisplay to one of the four possible combinations of arsenic and arabinose. After sampling for 24 hours, the biodisplay accurately reported on the presence / absence of these two small molecules (Fig. 3b). We note that the arsenic-sensing strain used (EDI_as_4) was engineered to be tunable by arabinose, explaining the difference in intensity of the “skull and crossbones” symbol between experiments sampling arsenic and arabinose versus arsenic alone13. The patterns could be readily imaged using a research grade and USB fluorescent microscope. Because of the ease with which the symbols could be visualized we also tested whether the device could be imaged directly with a cellphone using a blue LED flashlight for illumination and a fluorescence emission filter held in front of the cellphone camera. Both symbols could readily be imaged with this simple setup (Fig. 3c). The symbols could also be seen by eye using the flashlight and emission filter. Imaging was performed in an illuminated laboratory during daylight hours, with a small black curtain shielding the device from direct sunlight (Fig. 3d and Supplementary Fig. 5).

Spores enable long-term storage

In order to develop a biodisplay that can withstand long-term storage and shipping without requiring a cold chain or special conditions we explored the use of bacteria spores. Bacterial spores are well known for their incredible robustness to adverse environments21,22 and thus would be ideal for programming the biodisplay.

We generated spores from two B. subtilis strains, each containing a genomically integrated Phy-spank promoter driving the expression of either mCherry or GFP. The spores were spotted onto glass slides together with B. subtilis and E. coli cells. The slides were aligned and bonded to a microfluidic device. These biodisplays were then stored for one day or one month at 40°C and 80°C. After the storage period we introduced LB medium (Fig. 4a,b). Neither E. coli nor B. subtilis cells could be recovered after any storage condition tested. Only when spotted in the presence of glycerol and without an extended storage period could E. coli and B. subtilis cells be recovered.B. subtilis spores, on the other hand, germinated after all storage conditions, notably even after incubation at 80°C for one month. Germination was observed as early as 1.5 hours after the start of the culturing routine. To test whether a spore-based biodisplay retains sensing capability after storage at 80°C for one month, we induced expression with 1 μMIPTG and observed a rapid increase of fluorescence within 90 minutes. B. subtilisbiopixels not exposed to IPTG remained non-fluorescent (Fig. 4c).

Figure 4
  • Download figure
  • Open in new tab
Figure 4

Figure 4 Spore biodisplay. (a) Comparison of E.coli cell, B.subtilis cell and B.subtilis spore recovery under different storage conditions. Each table entry represents the number of chambers with observed growth divided by the total number of spotted chambers for a specific temperature and time condition. (b) Bright-field images of a magnified view of the central part of representative pixels after storage at 80°C for 1 month. Images were acquired immediately after spots were resuspended in medium and after 5 hours incubation at 37°C. (c) Time-lapse images of germinated Phy-spank-mCherry B. subtilis spores after storage at 80°C for one month. Cells were induced with 1 μM IPTG.

DISCUSSION

We developed a bio-hardware device by combining engineered bacterial strains with a microfluidic chip. The resulting biodisplay consists of 768 independently programmable biopixels and we showed that it can culture bacterial strains for extended periods of time. Continuous culturing, with the capability of dynamically changing media makes the biodisplay a useful platform for high-throughput bacteria cell analysis (manuscript arising) and may find application in high-throughput screening and characterization of synthetically engineered bacterial strains.

Biological systems are powerful sensors, but challenging to deploy for several reasons. First, engineered biological systems generally need to be cultivated under fairly well controlled conditions, and often require the presence of antibiotics in order to maintain the implemented synthetic network. Second, a major concern limiting the applicability of synthetic systems is the possible escape of genetically modified cells into the environment. Not only is the escape of GMOs a concern, but also the release of genetic material, which could readily be taken up by environmental bacteria through horizontal gene transfer. Our biodisplay solves both issues by providing a platform that enables long-term culturing, while eliminating release of genetic and chemical material into the environment. The small scale of the device requires low quantities of medium and antibiotics: ~2 ml for a 6 day experiment. The device outflow is sterilized and collected to prevent environmental contamination of biological and chemical components.

The ability to culture bacterial sensors on the biodisplay for extended periods of time with frequent readout makes the biodisplay a useful environmental monitoring tool. We have shown that our biodisplay can detect arabinose and sodium-arsenite in tap water using bacterial strains previously engineered by other research groups13,14 and student teams23. A large number of heavy metal sensors have already been engineered, including arsenic24,25, mercury25, and lead sensors26. Information processing systems also exist, including genetic toggle switches27, logic functions28, band-pass filters29, and event counters30. By combining event counters or toggle switches with sensors it is possible to implement memory, which could be useful in instances when the biodisplay can be monitored only intermittently, but a transient contamination should be logged and reported. The use of band-pass filters would enable the development of a biodisplay that reports the concentration of an analyte without requiring quantitative analysis of the reported signal. The biodisplay can also reduce the complexity of engineered strains, since functions can potentially be divided amongst several strains31. For example, to generate a sensor that senses and reports the presence/absence of three different substances wouldn’t require incorporation of all three functions into a single strain but could instead be implemented in three individual strains. It should also be possible to develop chemiluminescentbiodisplays or color biodisplays using chromogenic proteins. Communication between pixels as previously demonstrated using hydrogen peroxide10 could also be used to couple sensing biopixels, logic biopixels, and reporter biopixels.

Unlike previous biopixel arrays10 where each pixel contains the same bacterial strain, each pixel on our display can be specifically programmed with a different strain, drastically increasing the multiplexing capacity and information content of our biodisplay with a maximum of 768 unique strains, each of which could contain multiple, genetically encoded functions. A previous demonstration of integrating an E. coli arsenic biosensor in a microfluidic device was limited to a single culture, employed a complex scheme that decoupled culturing from measurement, and used a research-grade fluorescent microscope for readout32. A scheme called InfoBiology was used for the transmission of information using arrays of bacterial cellsspotted on microtiter sized agar plates33. 144 colonies of a handful of strains were spotted in this scheme, but lacked integration with a microfluidic device for cell culturing and environmental sampling.

Programmable biopixel displays drastically simplify device readout and interpretation. Instead of reporting the presence of arsenic using a display-wide pattern of signal oscillations10, our biodisplay generates an easy to understand “skull and crossbones” symbol. We showed that this concept can be easily multiplexed using different symbols to report the presence of multiple small molecules. The number of biopixels is scalable with previous work on two layer PDMS chips having demonstrated up to 4160 unit cells per device34,35. Immediate optical readout without specialized equipment combined with the fact that computing and decision-making steps are conducted by the biodisplayitself make it low-cost, easy to deploy, and easy to interpret. Bio-hardware hybrid devices therefore combine the advantages of biological systems with the advantages of mechanical, electrical and optical systems.

We have previously developed a low-cost, portable hardware system that contains all necessary components for microfluidic device operation, making the biodisplay readily deployable in resource limited settings36. By using bacterial spores the biodisplay can be stored and shipped under ambient conditions and is viable for extended periods of time. The material cost of the biodisplay itself is negligible at less than 1 USD per device. In this particular example a bio-hardware platform applied to continuous environmental monitoring of arsenic levels in water could replace a 26’000 USD instrument with an annual running cost of over 3’000 USD (Oval7000, Modern Water Monitoring Limited). The relatively slow response time of our biodisplay is acceptable in this and other applications, where continued chronic exposure of a substance is to be avoided. For time critical applications the response time of the biosensors would need to be improved, for example by developing phosphorylation based sensors and reporters rather than transcriptional based genetic networks37.

The concept of bio-hardware is not the same as bionics, bioinspired engineering, or biological robots (biots). The fusion of biological systems and hardware as described here is conceptually closer to cybernetics and cyborgs, generating a functional device that is a fusion, or hybrid, of interacting biological and hardware elements. The ability to engineer biological systems on the molecular level and combine them with hardware opens new opportunities for how engineered biological, mechanical, electrical and optical systems are integrated and the types of functions they can perform.

METHODS

Methods and any associated references are available in the online version of the paper.

ATUHOR CONTRIBUTIONS

F.V., E.P. and S.J.M. designed research, analyzed the data and wrote the manuscript. F.V. performed the microfabrication and F.V. and E.P. performed the experiments.

COMPETING FINANCIAL INTERESTS

The authors declare no competing financial interests.

ONLINE METHODS

Materials

All bacterial strains and plasmids used in the study are listed in Supplementary Table 1. Cells for arsenic detection were a gift from Baojun Wang (University of Edinburgh): pBW103ParsR-Amp30C (Addgene plasmid # 78638), pBW300ParsR-Amp32T (Addgene plasmid # 78652), pBW102ParsR-Amp32C (Addgene plasmid #78637) and pBW101ParsR-gfp (Addgene plasmid # 78636). LB medium was purchased from ApplichemPanreac (A0954). L-(+)-Arabinose (A3256-100G), 0.05M (35000-1L-R) and chloramphenicol (23275) were purchase from Sigma. Kanamycin sulfate (T832.1) was bought from Carl Roth. Isopropyl-β-D-thiogalactoside for spore induction was purchased from Roche. Schaeffer and Fulton Spore Stain Kit was bought from Sigma Aldrich.

Device fabrication

Device molds were made using standard photolithography techniques. The mold for the control layer was made using GM 1070 SU-8 photoresist (GersteltecSarl, Switzerland) with a height of 30 μm. The flow layer was made with AZ9260 photoresist (GersteltecSarl, Switzerland) with a thickness of 14 μm. A Suss MJB4 single side mask aligner was used to expose the wafers. The flow mold was baked for 2 hours at 135°C to anneal the flow channels. The molds were then treated with chlorodimethylsilane (DMCS) prior to being exposed to PDMS (Sylgard 184). The flow layer was prepared with a ratio of 20:1 (part A:B) PDMS and spin coated with a speed of 3000 rpm for 1 minute. The control layer was coated with a 5:1 ratio of PDMS. Both layers were baked for 30 minutes at 80°C and then aligned. After alignment the two PDMS layers were baked for an additional 1.5 hours at 80°C. The chip was then aligned to a spotted glass slide.

Cell culture, transformation and spore formation

E. coliand B. subtiliscells were cultured in LB medium at 37°C and 200 rpm with appropriate antibiotics, when required. All plasmid transformation and E.colicell studies were performed in DH5-αcells. B. subtilissporulation was performed as described previously38. For spore enrichment, a three day old B. subtiliscell suspension was centrifuge for 1 min at 15000 rpm, the pellet was washed three times with water and Schaeffer and Fulton spore staining was performed to verify the presence of spores.

Cell arraying

Overnight cultures of E. coliand B. subtiliswere centrifuged for 5 min at 3000 rpm. For the E. colidisplay the cell pellet was resuspended in 100 μl LB with 10% glycerol and appropriate antibiotics. For the spore biodisplay spores were resuspended in water. Cell suspensions and B. subtilisspore solutions were plated in conical, polypropylene 96-well plates. The samples were spotted with a 0.7 nl delivery volume pin (946MP2B Arrayit) on a glass slide by using a microarray robot (QArray2, Genetix). Glass slides were coated with epoxysilane (3-Glycidoxypropyl-dimethoxymethylsilane 97% AC216545000 Acros organic). The spotting parameters were as follows: 100 ms inking time, 10 ms stamping time, max number of stamps per ink 30. A wash procedure was included that consisted of washing the spotting pin with 70% ethanol for 2 s, washing with water for 2 s each followed by pin drying. Depending on the spotting pattern and number of samples used the spotting time varied between 10 to 20 minutes.

Cell-display culturing

The E. coliarray was aligned to a PDMS chip and incubate for 1 hour at 37°C. The spore-array was aligned to a MITOMI39 PDMS chip and incubated depending on the experimental procedure as follows: 40°C for 1 day, 40°C for 1 month, 80°C for 1 day, or 80°C for 1 month. After the incubation step the devices were placed on a temperature-controlled glass plate (H401-NIKON-TI_SR_GLASS/H401_T_CONTROLLER; Okolab) at 37°C. The control and flow lines were filled with water and actuated: for the E. colidisplay the control and flow lines, 10 psi and 2 psi were used, respectively. For the spore-display 15 psi and 3.5-4 psi were used instead. For the spore display we used a 768 unit cell MITOMI chip39, but performed the same culturing routine as on the biodisplay device. For the cell-culturing and sampling routines a custom-written LabVIEW program was used. During the culturing, LB medium with appropriate antibiotics and lysis buffer containing 30 mM of NaOH (06203-1KG Sigma Aldrich) and 12% SDS (L3771-100G Sigma) was used. Depending on the experimental procedure LB medium or water was supplemented with arabinose, sodium-arsenite, or IPTG.

Imaging

Image acquisition was performed on a Nikon ECLIPSE Ti automated microscope equipped with a LED Fluorescence Excitation System and a Hamamatsu ORCA-Flash 4.0 camera controlled by NIS Elements. Images were taken at 40× magnification (SPlan Fluor, ELWD 40×/0.60, ∞/0.2, WD 3.6-2.8, Nikon) in fluorescent and bright field mode. Images of all biopixel units were stitched together using either the Grid/Collection Stitching plugin in Fiji or a custom-written Python script. Fluorescent measurements were performed using Genepix software. A FITC USB fluorescent microscope (AM4113T-GFBW, Dino-Lite) was used to acquire fluorescent images. Images of 9 sub-sections of the device were taken, using lower magnification (10×), and stitched. Pictures were also taken using a cellphone camera. A band-pass filter, centered at 530 nm with a 40 nm bandwidth, was placed in front of the camera of the mobile phone, and the LEDs of the FITC USB microscope were used for illumination of the biodisplay.

ACKNOWLEDGEMENTS

The work was supported by the EcolePolytechniqueFederale de Lausanne and a Swiss National Science Foundation grant (CR23I2 140697). We thank Pernille Rainer and KilianCochet for the initial characterization of cell spotting, Philippe Lenzen for the preliminary characterization of the spore-display and NadanaiLaohakunakorn and Mathieu Quinodoz for help with LabVIEW programming. We also thank Professor Baojun Wang (University of Edinburg) and Professor Jan Roelof van der Meer (University of Lausanne) for the kind gift of arsenic-responsive E. coli strains.

REFERENCES

  1. 1.↵
    van der Meer, J. R. & Belkin, S. Where microbiology meets microengineering: design and applications of reporter bacteria. Nat. Rev. Microbiol. 8, 511–522 (2010).
    OpenUrlCrossRefPubMed
  2. 2.↵
    Bereza-Malcolm, L. T., Mann, G. & Franks, A. E. Environmental Sensing of Heavy Metals Through Whole Cell Microbial Biosensors: A Synthetic Biology Approach. ACS Synth. Biol. 4, 535–546 (2015).
    OpenUrlCrossRefPubMed
  3. 3.↵
    Whitesides, G. M. The origins and the future of microfluidics. Nature 442, 368–373 (2006).
    OpenUrlCrossRefPubMedWeb of Science
  4. 4.↵
    Garcia-Cordero, J. L. & Maerkl, S. J. Mechanically Induced Trapping of Molecular Interactions and Its Applications. J. Lab. Autom. 21, 356–367 (2016).
    OpenUrlCrossRefPubMed
  5. 5.↵
    Morin, S. A. et al. Camouflage and Display for Soft Machines. Science 337, 828–832 (2012).
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    Riedel-Kruse, I. H. et al. Design, engineering and utility of biotic games. Lab Chip 11, 14–22 (2011).
    OpenUrlCrossRefPubMed
  7. 7.↵
    Liu, X. et al. Stretchable living materials and devices with hydrogel–elastomer hybrids hosting programmed cells. Proc. Natl. Acad. Sci.doi:10.1073/pnas. 1618307114 (2017).
    OpenUrlCrossRef
  8. 8.↵
    Dénervaud, N. et al.A chemostat array enables the spatio-temporal analysis of the yeast proteome. Proc. Natl. Acad. Sci. U. S. A. 110, 15842–15847 (2013).
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    Rajkumar, A. S.,Dénervaud, N. & Maerkl, S. J. Mapping the fine structure of a eukaryotic promoter input-output function. Nat. Genet. 45, 1207–1215 (2013).
    OpenUrlCrossRefPubMed
  10. 10.↵
    Prindle, A. et al.A sensing array of radically coupled genetic ‘biopixels’. Nature 481, 39–44 (2011).
    OpenUrlCrossRefPubMedWeb of Science
  11. 11.↵
    Hansen, C. L.,Skordalakes, E., Berger, J. M. & Quake, S. R. A robust and scalable microfluidic metering method that allows protein crystal growth by free interface diffusion. Proc. Natl. Acad.Sci. U. S. A. 99, 16531–16536 (2002).
    OpenUrlAbstract/FREE Full Text
  12. 12.↵
    Balagaddé, F. K., You, L., Hansen, C. L., Arnold, F. H. & Quake, S. R. Long-term monitoring of bacteria bndergoing programmed population control in a microchemostat. Science 309, 137–140 (2005).
    OpenUrlAbstract/FREE Full Text
  13. 13.↵
    Wang, B., Barahona, M. & Buck, M. Engineering modular and tunable genetic amplifiers for scaling transcriptional signals in cascaded gene networks. Nucleic Acids Res. 42, 9484–9492 (2014).
    OpenUrlCrossRefPubMedWeb of Science
  14. 14.↵
    Merulla, D.,Hatzimanikatis, V. & van der Meer, J. R. Tunable reporter signal production in feedback-uncoupled arsenic bioreporters. Microb. Biotechnol. 6, 503–514 (2013).
    OpenUrlCrossRefPubMed
  15. 15.↵
    Lynch, H. N., Greenberg, G. I., Pollock, M. C. & Lewis, A. S. A comprehensive evaluation of inorganic arsenic in food and considerations for dietary intake analyses. Sci. Total Environ. 496, 299–313 (2014).
    OpenUrlCrossRefPubMed
  16. 16.↵
    Hojsak, I. et al.Arsenic in Rice. J. Pediatr. Gastroenterol. Nutr. 60, 142–145 (2015).
    OpenUrlCrossRef
  17. 17.↵
    Meharg, A. A. et al.Inorganic arsenic levels in rice milk exceed EU and US drinking water standards. J. Environ. Monit. 10, 428–431 (2008).
    OpenUrlPubMed
  18. 18.↵
    WHO | Arsenic. WHO(2016).
  19. 19.↵
    Naujokas, M. F. et al.The broad scope of health effects from chronic arsenic exposure: update on a worldwide public health problem. Environ. Health Perspect. 121, 295–302 (2013).
    OpenUrlCrossRefPubMedWeb of Science
  20. 20.↵
    Priority List of Hazardous Substances | ATSDR.
  21. 21.↵
    Setlow, P. Spores of Bacillus subtilis: their resistance to and killing by radiation, heat and chemicals. J. Appl. Microbiol. 101, 514–525 (2006).
    OpenUrlCrossRefPubMedWeb of Science
  22. 22.↵
    Atrih, A. & Foster, S. J. The role of peptidoglycan structure and structural dynamics during endospore dormancy and germination. Antonie Van Leeuwenhoek 75, 299–307 (1999).
    OpenUrlCrossRefPubMed
  23. 23.↵
    parts.igem.org.
  24. 24.↵
    Kaur, H., Kumar, R.,Babu, J. N. & Mittal, S. Advances in arsenic biosensor development - A comprehensive review. Biosens. Bioelectron. 63, 533–545 (2015).
    OpenUrlCrossRefPubMed
  25. 25.↵
    Wright, O.,Delmans, M., Stan, G.-B. & Ellis, T. GeneGuard: A Modular Plasmid System Designed for Biosafety. ACS Synth. Biol. 4, 307–316 (2015).
    OpenUrlCrossRefPubMed
  26. 26.↵
    Bereza-Malcolm, L.,Aracic, S. & Franks, A. E. Development and Application of a Synthetically-Derived Lead Biosensor Construct for Use in Gram-Negative Bacteria. Sensors (Basel). 16, 2174–2186 (2016).
    OpenUrl
  27. 27.↵
    Gardner, T. S., Cantor, C. R. & Collins, J. J. Construction of a genetic toggle switch in Escherichiacoll. Nature 403, 339–342 (2000).
    OpenUrlCrossRefPubMedWeb of Science
  28. 28.↵
    Nielsen, A. A. K. et al.Genetic circuit design automation. Science 352, aac7341-aac7341 (2016).
    OpenUrlAbstract/FREE Full Text
  29. 29.↵
    Basu, S.,Gerchman, Y., Collins, C. H., Arnold, F. H. & Weiss, R. A synthetic multicellular system for programmed pattern formation. Nature 434, 1130–1134 (2005).
    OpenUrlCrossRefPubMedWeb of Science
  30. 30.↵
    Friedland, A. E. et al.Synthetic Gene Networks That Count. Science 324, 1199–1202 (2009).
    OpenUrlAbstract/FREE Full Text
  31. 31.↵
    Shong, J., Rafael, M., Diaz, J. & Collins, C. H. Towards synthetic microbial consortia for bioprocessing. Curr. Opin. Biotechnol. 23 798–802 (2012).
    OpenUrlCrossRefPubMedWeb of Science
  32. 32.↵
    Buffi, N. et al.Development of a microfluidics biosensor for agarose-bead immobilized Escherichia coli bioreporter cells for arsenite detection in aqueous samples. Lab Chip 11, 2369–2377 (2011).
    OpenUrlCrossRefPubMedWeb of Science
  33. 33.↵
    Palacios, M. A. et al.InfoBiology by printed arrays of microorganism colonies for timed and on-demand release of messages. Proc. Natl. Acad. Sci. U. S. A. 108, 16510–16514 (2011).
    OpenUrlAbstract/FREE Full Text
  34. 34.↵
    Fordyce, P. M. et al.De novo identification and biophysical characterization of transcription-factor binding sites with microfluidic affinity analysis. Nat. Biotechnol. 28, 970–975 (2010).
    OpenUrlCrossRefPubMedWeb of Science
  35. 35.↵
    Garcia-Cordero, J. L. & Maerkl, S. J. Mechanically Induced Trapping of Molecular Interactions and Its Applications. J. Lab. Autom. 21, 356–367 (2016).
    OpenUrlCrossRefPubMed
  36. 36.↵
    Piraino, F.,Volpetti, F., Watson, C. & Maerkl, S. J. A Digital–Analog Microfluidic Platform for Patient-Centric Multiplexed Biomarker Diagnostics of Ultralow Volume Samples. ACS Nano 10, 1699–1710 (2016).
    OpenUrlCrossRef
  37. 37.↵
    Purnick, P. E. M. & Weiss, R. The second wave of synthetic biology: from modules to systems.Nat. Rev. Mol. Cell Biol.10, 410–422(2009).
    OpenUrlCrossRefPubMedWeb of Science
  38. 38.↵
    Harwood, C. R. & Cutting, S. M. Molecular biological methods for Bacillus. (Wiley, 1990).
  39. 39.↵
    Maerkl, S. J. & Quake, S. R. A Systems Approach to Measuring the Binding Energy Landscapes of Transcription Factors. Science 315, 233–237 (2007).
    OpenUrlAbstract/FREE Full Text
Back to top
PreviousNext
Posted February 27, 2017.
Download PDF

Supplementary Material

Email

Thank you for your interest in spreading the word about bioRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
A microfluidic biodisplay
(Your Name) has forwarded a page to you from bioRxiv
(Your Name) thought you would like to see this page from the bioRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
A microfluidic biodisplay
Francesca Volpetti, Ekaterina Petrova, Sebastian J. Maerkl
bioRxiv 112110; doi: https://doi.org/10.1101/112110
Reddit logo Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
A microfluidic biodisplay
Francesca Volpetti, Ekaterina Petrova, Sebastian J. Maerkl
bioRxiv 112110; doi: https://doi.org/10.1101/112110

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Synthetic Biology
Subject Areas
All Articles
  • Animal Behavior and Cognition (4241)
  • Biochemistry (9173)
  • Bioengineering (6806)
  • Bioinformatics (24064)
  • Biophysics (12156)
  • Cancer Biology (9565)
  • Cell Biology (13825)
  • Clinical Trials (138)
  • Developmental Biology (7658)
  • Ecology (11737)
  • Epidemiology (2066)
  • Evolutionary Biology (15543)
  • Genetics (10672)
  • Genomics (14362)
  • Immunology (9513)
  • Microbiology (22905)
  • Molecular Biology (9129)
  • Neuroscience (49127)
  • Paleontology (358)
  • Pathology (1487)
  • Pharmacology and Toxicology (2584)
  • Physiology (3851)
  • Plant Biology (8351)
  • Scientific Communication and Education (1473)
  • Synthetic Biology (2301)
  • Systems Biology (6206)
  • Zoology (1303)