Abstract
Bioreactors for reseeding of decellularized lung scaffolds have evolved with a wide variety of advancements. These include biomimetic mechanical stimulation, constant nutrient flow, multi-output monitoring, and large mammal scaling. Although dynamic bioreactors are not new to the field of bioengineered lungs, ideal conditions during cell seeding have not been extensively studied or controlled. To address the lack of cell dispersal in traditional seeding methods, we have designed a two-step bioreactor. The first step rotates a seeded lung every 20 minutes at different angles to ensure 20 percent of cells are anchored to a particular location based on the known rate of attachment. The second step involves perfusion culture to ensure nutrient dispersion and cellular growth. Compared to statically seeded lungs followed by conventional perfusion, rotationally seeded lungs followed by perfusion had significantly increased dsDNA content and more uniform cellular distribution. This new bioreactor system will aid in recellularizing the lung and other geometrically complex organs for tissue engineering.
Competing Interest Statement
The authors have declared no competing interest.
Footnotes