Computed tomography lacks sensitivity to image gold labelled mesenchymal stromal cells in vivo as evidenced by multispectral optoacoustic tomography

Alejandra Hernandez Pichardo, James Littlewood, Arthur Taylor, Bettina Wilm, Raphaël Lévy, Patricia Murray
doi: https://doi.org/10.1101/2022.06.15.495483
Alejandra Hernandez Pichardo
1Department of Molecular Physiology and Cell Signalling, Institute of Systems, Molecular and Integrative Biology, University of Liverpool, Liverpool, UK
2Centre for Pre-clinical Imaging
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
James Littlewood
1Department of Molecular Physiology and Cell Signalling, Institute of Systems, Molecular and Integrative Biology, University of Liverpool, Liverpool, UK
3iThera Medical GmbH, Munich, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Arthur Taylor
1Department of Molecular Physiology and Cell Signalling, Institute of Systems, Molecular and Integrative Biology, University of Liverpool, Liverpool, UK
2Centre for Pre-clinical Imaging
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Bettina Wilm
1Department of Molecular Physiology and Cell Signalling, Institute of Systems, Molecular and Integrative Biology, University of Liverpool, Liverpool, UK
2Centre for Pre-clinical Imaging
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Raphaël Lévy
4Université Sorbonne Paris Nord and Université de Paris, INSERM, LVTS, F-75018 Paris, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Patricia Murray
1Department of Molecular Physiology and Cell Signalling, Institute of Systems, Molecular and Integrative Biology, University of Liverpool, Liverpool, UK
2Centre for Pre-clinical Imaging
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: P.A.Murray@liverpool.ac.uk
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Elucidating the mechanisms of action and long-term safety of cell therapies is necessary for their clinical translation. Non-invasive imaging technologies such as bioluminescence imaging (BLI), computed tomography (CT) and multispectral optoacoustic tomography (MSOT) have been proposed as tools for longitudinal cell monitoring but their performances have not been compared. Here, we evaluate combinations of these modalities to track the in vivo distribution of gold-labelled mesenchymal stromal cells (MSCs). We found that injected MSCs labelled with gold nanoparticles and expressing the reporter gene firefly luciferase could be detected with BLI and MSOT but not CT. We conclude that the MSCs did not carry enough contrast agent to be tracked by CT, demonstrating that CT tracking of gold-labelled cells is not a practical approach as high amounts of gold, which might impair cell viability, are necessary.

Competing Interest Statement

James Littlewood works at iThera Medical GmBh.

Footnotes

  • http://doi.org/10.5281/zenodo.6624805

Copyright 
The copyright holder for this preprint is the author/funder, who has granted bioRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY 4.0 International license.
Back to top
PreviousNext
Posted June 15, 2022.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about bioRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Computed tomography lacks sensitivity to image gold labelled mesenchymal stromal cells in vivo as evidenced by multispectral optoacoustic tomography
(Your Name) has forwarded a page to you from bioRxiv
(Your Name) thought you would like to see this page from the bioRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Computed tomography lacks sensitivity to image gold labelled mesenchymal stromal cells in vivo as evidenced by multispectral optoacoustic tomography
Alejandra Hernandez Pichardo, James Littlewood, Arthur Taylor, Bettina Wilm, Raphaël Lévy, Patricia Murray
bioRxiv 2022.06.15.495483; doi: https://doi.org/10.1101/2022.06.15.495483
Digg logo Reddit logo Twitter logo Facebook logo Google logo LinkedIn logo Mendeley logo
Citation Tools
Computed tomography lacks sensitivity to image gold labelled mesenchymal stromal cells in vivo as evidenced by multispectral optoacoustic tomography
Alejandra Hernandez Pichardo, James Littlewood, Arthur Taylor, Bettina Wilm, Raphaël Lévy, Patricia Murray
bioRxiv 2022.06.15.495483; doi: https://doi.org/10.1101/2022.06.15.495483

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Cell Biology
Subject Areas
All Articles
  • Animal Behavior and Cognition (4087)
  • Biochemistry (8768)
  • Bioengineering (6481)
  • Bioinformatics (23348)
  • Biophysics (11752)
  • Cancer Biology (9150)
  • Cell Biology (13256)
  • Clinical Trials (138)
  • Developmental Biology (7417)
  • Ecology (11371)
  • Epidemiology (2066)
  • Evolutionary Biology (15091)
  • Genetics (10402)
  • Genomics (14012)
  • Immunology (9122)
  • Microbiology (22050)
  • Molecular Biology (8780)
  • Neuroscience (47381)
  • Paleontology (350)
  • Pathology (1420)
  • Pharmacology and Toxicology (2482)
  • Physiology (3705)
  • Plant Biology (8054)
  • Scientific Communication and Education (1431)
  • Synthetic Biology (2209)
  • Systems Biology (6016)
  • Zoology (1250)