Abstract
We propose and theoretically study an approach to massively parallel single molecule peptide sequencing, based on single molecule measurement of the kinetics of probe binding [1] to the N-termini of immobilized peptides. Unlike previous proposals, this method is robust to both weak and non-specific probe-target affinities, which we demonstrate by applying the method to a range of randomized affinity matrices consisting of relatively low-quality binders. This suggests a novel principle for proteomic measurement whereby highly non-optimized sets of low-affinity binders could be applicable for protein sequencing, thus shifting the burden of amino acid identification from biomolecular design to readout. Measurement of probe occupancy times, or of time-averaged fluorescence, should allow high-accuracy determination of N-terminal amino acid identity for realistic probe sets. The time-averaged fluorescence method scales well to extremely weak-binding probes. We argue that this method could lead to an approach with single amino acid resolution and the ability to distinguish many canonical and modified amino acids, even using highly non-optimized probe sets. This readout method should expand the design space for single molecule peptide sequencing by removing constraints on the properties of the fluorescent binding probes.
Author summary We simplify the problem of single molecule protein sequencing by proposing and analyzing an approach that makes use of low-affinity, low-specificity binding reagents. This decouples the problem of protein sequencing from the problem of generating a high-quality library of binding reagents against each of the amino acids.
Introduction
Massively parallel DNA sequencing has revolutionized the biological sciences [2,3], but no comparable technology exists for massively parallel sequencing of proteins. The most widely used DNA sequencing methods rely critically on the ability to locally amplify (i.e., copy) single DNA molecules - whether on a surface [4], attached to a bead [5], or anchored inside a hydrogel matrix [6] - to create a localized population of copies of the parent single DNA molecule. The copies can be probed in unison to achieve a strong, yet localized, fluorescent signal for readout via simple optics and standard cameras. For protein sequencing, on the other hand, there is no protein ‘copy machine’ analogous to a DNA polymerase, which could perform such localized signal amplification. Thus, protein sequencing remains truly a single molecule problem. While true single molecule DNA sequencing approaches exist [7–9], these often also rely on polymerase-based DNA copying, although direct reading of single nucleic acid molecules is beginning to become possible with nanopore approaches [10] that may be extensible to protein readout [11–13]. Thus, the development of a massively parallel protein sequencing technology may benefit from novel concepts for the readout of sequence information from single molecules.
Previously proposed approaches to massively parallel single molecule protein sequencing [14–16] utilize designs that rely on covalent chemical modification of specific amino acids along the chain. Such chain-internal tagging reactions are currently available only for a small subset of the 20 amino acids, and they have finite efficiency. Thus, such approaches would likely not be able to read the identity of every amino acid along the chain.
An alternative approach to protein sequencing [1,17–19] is to use successive rounds of probing with N-terminal-specific amino-acid binders (NAABs) [1]. Recent studies have proposed that proteins derived from N-terminal-specific enzymes such as aminopeptidases [20], or from antibodies against the PITC-modified N-termini arising during Edman degradation [21], could be used as NAABs for protein sequencing. Yet designing or evolving highly specific, strong N-terminal binders to all 20 amino acids (and more if post-translational modifications, e.g., phosphorylation, are considered) is a challenge. Rather than attempting to improve the properties of the NAABs themselves, we will introduce a strategy - which we term “spectral sequencing” - to work around the limitations of existing NAABs and enable single molecule protein sequencing without the need to develop novel binding reagents.
Spectral sequencing measures the affinities of many low-affinity, relatively non-specific NAABs, collectively determining a “spectrum” or “profile” of affinity across binders, for each of the N-terminal amino acids. This profile is sufficient to determine the identity of the N-terminal amino acid. Thus, rather than requiring individual binders to be specific in and of themselves, we will infer a specific profile by combining measurements of many non-specific interactions. The spectral sequencing approach measures the single molecule binding kinetics in a massively parallel fashion, using a generalization of Points Accumulation for Imaging in Nanoscale Topography (PAINT) techniques [22,23] to N-terminal amino acid binders.
In what follows, we first derive the capabilities of single-molecule fluorescence based measurement of probe binding kinetics as a function of probe properties and noise sources. We then apply this analysis to the problem of sequencing proteins by measuring profiles of NAAB binding kinetics. Using a range of randomized NAAB affinity matrices as well as an affinity matrix derived directly from the existing measured NAAB kinetics [1], we simulate sequencing of single peptides and obtain 97.5% percent accuracy in amino acid identification over a total observation period of 35 minutes, even in the presence of up to 5% percent error in the instrument calibration and 25% variation in the true underlying kinetics of the binders, due for example to the effects of nonterminal amino acids.
Problem Overview
We consider the problem in which a set of peptides is immobilized on a surface and imaged using total internal reflection fluorescence (TIRF) microscopy. The surface must be appropriately passivated to minimize nonspecific binding [19,24–30]. The limited vertical extent of the evanescent excitation field of the TIRF microscope allows differential sensitivity to fluorescent molecules which are near the microscope slide surface, which allows us to detect NAABs that have bound to peptides on the surface. Existing sets of NAABS (e.g. [1]), derived from aminopeptidases or tRNA synthetases with affinities biased towards specific amino acids, have low affinity or specificity (figure 1A), so one cannot deduce the identity of an N-terminal amino acid from the binding of a single NAAB. Instead, we propose to deduce the identity of the N terminal amino acid of a particular peptide by measuring optically the kinetics of a set of NAABs against the peptide. After observing the binding of each NAAB against the peptide, we will carry out a cycle of Edman degradation [31,32], revealing the next amino acid along the chain as the new N-terminus, and then repeat the process. The process of observing binding kinetics with TIRF microscopy (figure 1B,C) is similar to that used in Points Accumulation for Imaging of Nanoscale Topography (PAINT [22]), e.g., DNA PAINT [23]. This process produces a high-dimensional vector of kinetically-measured affinities at each cycle (figure 1D,E) that can be used to infer the N-terminal amino acid.
This method, while powerful and potentially applicable for current NAABs, ultimately breaks down for probes whose binding is extremely weak, i.e., for which the bound time is so short that only a small number of photons is released while the probe is bound. While fast camera frame rates can be used, the system ultimately becomes limited in the achievable fluorescent signal to noise ratio, unless the measurements are averaged over long experiment times. To extend these concepts into the ultra-weak binding regime, therefore, we propose not to measure the precise binding and unbinding kinetics but rather the time-averaged luminosity of each spot, which indicates the fraction of time a probe was bound. We find that this luminosity-based measurement scheme is highly robust and compatible with short run times.
Results
Our results are divided into three sections. We first consider the regimes of binder concentration and illumination intensity within which one would expect the proposed method to operate. We then discuss two possible methods for analyzing single molecule kinetic data. Finally, we perform simulations using the derived parameters and data analysis methods in order to estimate the sensitivity of the proposed sequencing method.
Distinguishability of Amino Acids Based on their NAAB Binding Profiles
A set of binders (NAABs) is characterized by their affinities for their targets (e.g., the 20 amino acids), which can be expressed in the form of an affinity matrix. The affinity matrix A is defined such that the i,jth entry of A is the negative log affinity of the ith binder for the jth target: where kD is the dissociation constant (we define τD as the dissociation time).
Throughout this paper, the values of the affinities encoded in the affinity matrix will be referred to as the reference values, to distinguish them from the measured values obtained in the experiment and from the true values, which may depend on environmental conditions but which are not known by the experimenter; the reference values are known and will be used in our computational process of identifying amino acids. As shown in S1.1 Appendix, we estimate that it would be possible to determine the identities of the N terminal amino acids from affinity measurements with 99% accuracy, provided that the affinity measurements occur according to a distribution centered on the reference value with standard deviation no greater than 64% of the mean.
Constraints on Realistic Binding Measurements
In this section, we discuss the primary constraints that are imposed by the measurement modality.
Binder Shot Noise
For the purposes of our analysis, we will assume that all binders within 100 nm of the surface emit photons at an equal rate, while more distant binders emit no photons at all. We will also assume that all emitted photons are collected. In reality, excitation due to higher-order beams that do not reflect at the interface will lead to some diffuse background from the bulk solution, and not all photons will be collected due to finite efficiencies in the optical path and at the detector, but contributions from these factors will depend significantly on the specifics of the optical setup and are difficult to estimate; we account approximately for some of these factors in the simulations below by calibrating with published DNA PAINT experiments. We will use the term “observation field” to refer to the region occupied by fluorescent NAABs binding to a single, well-isolated, surface-anchored peptide. For the sake of simplicity, we will assume that the observation field is imaged onto a single pixel on the camera, and will assume that it constitutes a cylindrical region 300 nm in diameter and 100 nm in depth, corresponding to visible TIRF illumination.
In order to be able to distinguish the bound state from the unbound state, the number of photons emitted over the period of observation in the bound state must be significantly larger than the number of photons emitted in the unbound state. We denote by τobs the observation period (which may extend over multiple camera frames), by R the rate at which fluorophores in the observation field emit photons, and by nfree the number of free binders in the observation field, which we will refer to as the “occupation number” for brevity. The occupation number may be given in terms of the volume V of the observation field and the molecular number density of the binders ρ by where c is the molar concentration and NA is Avogadro’s number. Then there are two regimes in which we are interested, corresponding to nfree ≫ 1 and nfree ≤ 1. The choice of nfree is up to the experimenter and may be chosen differently for different NAABs. It will need to be optimized to maximize the dynamic range of the kD readout experiment.
If nfree ≫ 1, the number of photons emitted by the nfree free fluorophores in the observation field during the observation period will be drawn from a Poisson distribution with mean and variance On the other hand, in the bound state, the mean number of photons emitted is One may then derive (S1.2 Appendix) the requirement that
The photon rate R is associated with the illumination intensity by where ϵ is the molar absorptivity. (See S1.3 Appendix for a derivation.) The minimum intensity that can be used is thus set by the constraints on R in equation (5). We obtain
It is worth bearing in mind that an occupation number of nfree ≈ 1 in every cylinder with diameter 300 nm and height 100 nm corresponds to a molar density of 235 nM.
In the case of nfree ≤ 1, the noise may deviate significantly from a Poisson distribution (see S1.2 Appendix for a discussion). In this regime, it is likely easy to distinguish the bound and unbound states, and instead the constraints on R and τobs are set by the requirement that Rτobs be greater than the read and dark noises of the camera. Modern sCMOS cameras have very low dark noises of 0.1 e− per second, and read noises of only 1 to 2 e− on average. We denote by p the per-frame noise, measured in electrons, and by f the camera frame rate. Note that τobs may be determined independently of f, because the photon counts from multiple frames may be averaged in order to extend the observation period. Instead, f is constrained by practical considerations such as the per-frame read noise and the saturation point of the sensor. In order to overcome the read and dark noises, we need
The minimum intensity can thus be determined by the constraint
A detector noise of p = 1 electron per frame is now standard. To satisfy the requirement in equation (8) for our further calculations, we will take as a requirement that in the limit of nfree ≤ 1, we should have
Photobleaching
The upper bound on the tolerable intensity is placed by photobleaching. Assuming continuous imaging, the fluorophore should remain active for the entire duration during which the fluorophore is bound. We denote by Nq the average number of photons that a fluorophore emits before it bleaches. Then, we must have
In terms of the intensity,
For a typical dye, such as ATTO647N, values of Nq on the order of 107 and ϵ ~ 1.5 × 107 M−1 m−1 have been reported [23].
Stochastic Binding
Due to the stochastic nature of binding events, the length of the experiment must be chosen to be much longer than the average time between binding events. Hence, where c is the concentration of free binders in the solution.
Methods of Data Analysis
A measurement performed using this scheme yields a time series such as that shown in Figure 2A. We now discuss the two primary options for extracting the kinetics from this data and the experimental conditions that are optimal for each scheme, given the constraints discussed above.
Occupancy Measurements
The first measurement, used commonly in the field of single-molecule kinetics [23,33], relies on detecting changes in the occupancy state of the target. The measurement scheme is depicted schematically in Figure 2B. This measurement is performed “along the time axis,” in the sense that it relies on temporal information - when probes bind and unbind - and is relatively insensitive to analog luminosity information beyond that needed to make these digital determinations. This method is optimal for measurements on binders with very high affinities, which can be performed at low concentrations. The upper limit on the dynamic range of this method is set by the frame rate, i.e., where f is the imaging rate. In order to extract temporal information, we set τobs = 1/f. This method will typically operate in the limit nfree ≤ 1, so from equation (10), we find that we must have Rτobs ≥ 9. Hence, and hence
On the other hand, the lower bound on the dynamic range is provided by photobleaching, as captured in equation (11). In total, we have
In practice, for this measurement modality, we will choose f = 100 Hz and R = 104 s−1, corresponding to a laser power of 13 Wcm−2. With Nq ~ 107, the requirement becomes koff ≪ 100 s−1 and koff ≫ 10−3 s−1, yielding an effective dynamic range of approximately three orders of magnitude of koff.
Finally, the experiment time is constrained by the requirement that
For a value of kon on the order of 105 M−1 s−1 and a concentration on the order of 100 nM, this requirement implies that an experiment time of at least 100 seconds is necessary in order to see several binding events with high probability.
If the binding and unbinding events may be identified, then one may determine the average binding time Tb and the average time between binding events Ti, which we will refer to as the inter-event time. If photobleaching may be neglected, then we have and where c is the free binder concentration. Thus,
Alternatively, if the on-rate kon is known, then it is possible to determine koff even in the presence of photobleaching. (See S1.4 Appendix for details.)
Luminosity measurements
An alternative to the occupancy-time measurements described above involves deducing kD directly from the fraction fB of time that the target is bound by a probe. This quantity may in turn be deduced from the average luminosity of the spot containing the free binder over the period of observation, as depicted in Figure 2C. Whereas occupancy measurements are performed “along the time axis,” neglecting luminosity information, luminosity measurements are performed “along the luminosity axis,” neglecting temporal information about the series of binding and unbinding events. Because it does not attempt to track individual binding and unbinding events, this method is particularly suited to measurements of weak binders performed at high background concentrations, where binding and unbinding events may occur faster than the camera frame rate. Moreover, this method relies on each NAAB of a given type having approximately the same brightness, which could be achieved using a high-efficiency method for monovalently labeling the NAAB N- or C-terminus [34,35].
If the target is bound a fraction fB of the time, then the dissociation constant is given by where c is the background binder concentration. We denote by S the average brightness of the spot when a fluorescent binder is attached to the target, and by N the average brightness of the spot when the target is free. Neglecting photobleaching, the average brightness of the spot over the whole experiment is given by
If S and N are known, then fB may thus be deduced directly from the measured photon rate M averaged over the entire experiment, via S and N can be measured directly for example by anchoring NAABs sparsely to a surface and measuring the brightness of the resulting puncta (to deduce S), or puncta-free regions (to measure N).
One significant advantage of this method is that the observation period τobs can be chosen to be arbitrarily long by averaging the photon counts of many successive frames (i.e., we have τobs = Texp). In practice, we will use τobs = 100s. With this value, we can use a relatively high concentration of 2 μM (corresponding to nfree ≫ 1) even for a relatively low intensity of 1.3W cm−2 (corresponding to R = 103 s−1, while still satisfying (5). Operating in this regime significantly reduces the vulnerability of the experiment to stochasticity and photobleaching. However, unlike in the case of occupancy measurements, there is no way to account for photobleaching, if it occurs. Nonetheless, we do not expect photobleaching to have a significant impact on our results, since most of the NAABs have fairly high off-rates [1,20].
In contrast to occupancy measurements, luminosity measurements are also sensitive to error in the calibration of the measurement apparatus, for example if the brightness of the bright and dark states is not known exactly. The bright and dark states S and N could likely be calibrated by doping in labeled reference peptides to the sample to be sequenced. Still, there may be some error in the measurements of S and N. For a discussion of computational strategies for coping with calibration error, see Appendix 1.5.
Simulations
Simulation Outline
In order to determine whether the TIRF measurement scheme described above can be used to identify single amino acids on the N-termini of surface-anchored peptides, we simulated N-terminal amino acid identification experiments.
We first used a specific NAAB affinity matrix given in [1]. Importantly, random affinity matrices generated by permuting the values of the NAAB affinity matrix perform similarly well in residue-calling simulations (fig 5 and 6). To generate the random affinity matrices with statistics matching the statistics of the NAAB affinity matrix, each matrix element was chosen by randomly sampling values from the NAAB affinity matrix of [1], without replacement. The simulations described here can therefore be assumed to apply to general ensembles of N-terminal binders with affinity value statistics similar to those displayed by these existing NAABs.
In the simulations, there is assumed to be one free target in the volume analyzed, which is a cylinder of diameter 300 nm and height 100 nm as discussed above. The simulation considers each frame of the camera in succession, and models the number of photons registered at the camera. At the start of the simulation, or as soon as the target becomes free, a time Tfree is drawn from an exponential distribution with mean 1/(konc), where c is the concentration of binders. Once a time equal to Tfree has passed, the binder is considered occupied, and a time Tbound is drawn from an exponential distribution with mean 1/koff. In addition, upon binding, a time Tphotobleach is drawn from an exponential distribution with mean Nq/R, where Nq is the number of photons the fluorophore emits on average before bleaching and R is the single-fluorophore photon rate. If the time Tphotobleach is less than the time Tbound, the fluorophore ceases to emit photons after time Tphotobleach. Within a given frame, the simulation tracks binding, unbinding, and photobleaching events, and computes the number of signal photons detected by the camera by drawing from a Poisson distribution with mean RTon, where R is the single fluorophore photon rate and Ton is the amount of time during the frame in which an unbleached fluorophore was attached to the target.
The dominant contribution to noise in the simulation is expected to come from fluorophores attached to free binders that enter and leave the observation field [33]. At the end of each frame, the simulation draws the number of free binders that enter the observation field during the frame from a Poisson distribution with mean nfree/f, where f is the frame rate and nfree is the free binder occupation number of the frame. For each binder that enters the observation field, we draw a dwell time t from an exponential distribution with mean τdwell as calculated in equation (40) from diffusion theory (see Appendix 1.2), and a total photon contribution from a Poisson distribution with mean Rt. Finally, we calculate the detector shot noise from a Gaussian distribution with mean p and standard deviation equal to 0.1p.
Validation of the Simulation Pipeline
To validate the simulations, we reproduced the DNA PAINT kinetics data collected by [23] using the parameters reported in that paper. There, values of kon = 106 M−1 s−1 and koff = 2 s−1 were reported. Imaging was conducted at 650 nm with a power of 4 mW to 8 mW over an imaging region of (150μm)2, corresponding to an intensity of approximately 26.67 Wcm−2, corresponding to a photon rate of R ~ 18 000 s−1, assuming a dye comparable to ATTO655. However, accounting for the low quantum efficiency of ATTO655 and possible losses of light in the light path of the microscope, we performed our simulations with R ~ 1500 s−1. From our simulated data, we were able to reproduce the measured off- and on-rates, as shown in Figure 2D. Moreover, consistent with [23], photobleaching only became apparent in the simulation at laser powers greater than 100 mW.
Measurements of kD
Occupancy Measurements
We next simulated occupancy measurements of the binding kinetics of the NAAB against the target. We performed 100 simulations for each of five different values of kon between 104 M−1 s−1 and 106 M−1 s−1, which is consistent with standard values observed for antibodies [36], and for each of five different values of kD between 100 μM and 10 nM. We assumed a framerate of 100 Hz, detector read noise of 1 e−, and a laser power of 130 kW m−2, corresponding to a single-fluorophore photon rate of 104 s−1. NAABs were washed onto the sample at a concentration of 300 nM, and each wash was observed for Texp = 100 s.
In order to analyze the data, we ran a control simulation in which kon was set to 0, so that no NAABs bound to the target. In practice, this calibration could be performed by observing a spot that does not have a target. From this, we calculated the mean and standard deviation of the noise on a per-frame basis. We then identified binding and unbinding events as follows. First, we identified all frames in which the photon count was more than 2 standard deviations above the noise mean. These frames will be referred to as “on” frames, whereas all other frames will be referred to as “off” frames. If three such “on” frames occurred in a row, the event was identified as a binding event. The binding event was considered to continue until at least two “off”-frames in a row were observed. Once all the binding and unbinding events were identified, the average inter-event time and the average binding time were calculated, and from these the kinetics were deduced (Figure 2A).
The accuracy of the kD measurements was found to improve with increasing kon, and to improve with increasing kD for values of koff below 10 s−1 (Figure 3A). For values of koff significantly above 10 s−1, it was no longer possible to distinguish individual binding and unbinding events from noise (Figure 3A, upper right-hand corner). Moreover, for values of kon below 105 M−1 s−1, the condition Texp ≫ 1/(konc) was no longer satisfied. Finally, for very small values of kD, photobleaching limited the accuracy of the analysis. For kon > 105 M−1 s−1 and koff ~ 10 s−1, it was possible to obtain the correct value of kD to within approximately 5 − 10%. However, the accuracy deteriorated sharply for combinations of kon and koff deviating from these ideal conditions.
Luminosity Measurements
We then simulated luminosity measurements of kD using comparable parameters. Because these measurements depend only on the average luminosity over the entire experiment, the entire experiment was lumped into a single camera frame. In practice, however, the same results can be obtained by averaging over the photon counts of multiple frames. The laser intensity was set to 13 kW m−2, corresponding to a single-fluorophore photon rate of R = 1000 s−1, and the free binder concentration was set to 2 μM. The photon rate of the off-state was determined first by running the simulation with the value of kon set to 0. The photon rate in the on-state was then determined by running the simulation with the value of kon set to 1010 M−1 s−1, and the value of kD set to 10−20 M. Because the exposure time used in this experiment is very long compared to the dwell time of free binders in the observation field, it was assumed that all free binders that enter the observation field emit a number of photons equal to Rτdwell (i.e., the noise was taken to be approximately Poissonian), which substantially reduces the computational complexity of the algorithm. Once the average luminosity over the experiment was determined, the value of fB was deduced.
For observation times shorter than 50s, the analysis sometimes returns values of fB arbitrarily close to or greater than 1 or arbitrarily close to or less than 0. This can happen as a consequence of statistical error in the luminosity measurements, even in the absence of systematic error. For this reason, in order to avoid negative or outlandishly large values of kD from compromising the analysis, we chose the maximum value of fB to be equal to the value expected when kD = 1 nM, and we chose the minimum value of fB to be equal to the value obtained when kD = 10 mM. Any values of fB outside of this range were adjusted to the maximum or minimum value, appropriately.
In order to enable comparison to the occupancy measurements, the simulation was run 100 times for each of five values of kon between 104 M−1 s−1 and 106 M−1 s−1 and for each of five values of kD between 100 μM and 10 nM. The accuracy was found to be comparable to that obtained in the occupancy experiments (Figure 3A), except that the accuracy did not deteriorate for very high values of koff (Figure 3B, upper right-hand corner). For values of kon on the order of (or greater than) 105 M−1 s−1 and values of kD greater than 1 μM, kD could easily be determined to within the accuracy condition required by equation (31).
To ascertain the effect of τobs on the accuracy, the simulation was run 100 times for each of the same 25 combinations of kon and koff, with 8 different values of τobs between 1s and 1000 s and a free binder population of 2 μM (Figure 3C). As expected, the accuracy was found to undergo a sharp transition when τobs was on the order of 25 s, corresponding to 1/(konc) ≪ τobs. For values of τobs > 25 s and values of kD greater than 1 μM, the error in the measurement of kD decreased like 1/Tobs (Figure 3C). For observation times greater than 25 s, the value of kD could be calculated with standard deviation less than 64% of the mean for values of kD on the order of or greater than 1 μM, although photobleaching leads to saturation and significant losses of accuracy for smaller values of kD (Figure 3D).
Separately, to ascertain the effect of the free binder concentration on the accuracy, the simulation was run 1000 times on each of the same 25 combinations of kon and kD, with τobs = 50 s at seven different values of the concentration between 10 nM and 5 μM. For values of kon such that τobs ≫ 1/(konc), the effect of increasing kon was found to be similar to the effect of increasing τobs (data not shown).
Identifying Amino Acids
Because standard deviations in kD below 64% of the mean could consistently be achieved in the luminosity measurements across a broad range of values of kon and kD, it is reasonable to expect that luminosity measurements of NAAB binding kinetics with the affinity matrix in figure 1a could allow for the identification of amino acids at the single molecule level. We thus simulated an experiment in which a peptide with an unknown amino acid is attached to a surface, and is observed successively in multiple baths, each containing a single kind of fluorescent NAAB. In this simulation, amino acids were randomly chosen from a uniform distribution. Binders were added to the solution at a concentration of 1 μM and the laser power was set to 13 kW m−2. For each NAAB, effective values of the dissociation constant k̃D, the on-rate k̃on, the effective brightness R̃, and the calibration levels S̃ and Ñ were determined for the NAAB-amino acid pair. The spot containing the NAAB was then observed over a period of time τobs, which ranged from 50 to 500 seconds, and the total number of photons observed was stored. This process was repeated for each NAAB, generating a vector of observed photon counts.
Systematic error in the experiment was parametrized using three quantities. For each NAAB, the effective dissociation constant k̃D for the NAAB-amino acid pair was drawn from a normal distribution centered on the reference value kD, with standard deviation equal to σK kD, where σK parametrizes the effect of non-terminal amino acids and other environmental factors on the dissociation constant. Likewise, the effective brightness of the NAAB relative to the average NAAB brightness was determined by drawing R̃ from a normal distribution with mean R and standard deviation σBR, where R is the photon rate of a standard fluorophore (assumed here to be ATTO647N) in the observation field. Finally, in order to determine the effective calibration levels, the true calibration levels S and N were first determined as the luminosity of the bound and unbound states, as described above (Luminosity Measurements). The measured calibration levels S̃ and Ñ were then determined by drawing from a normal distribution with mean equal to S and N and with standard deviation equal to σCS and σCN, respectively. The values of σK, σB, and σC will be given below in percentages.
Analysis was performed by comparing the measured photon counts to the photon counts that would have been expected for each amino acid, as described above. For each NAAB-amino acid pair, the expected photon count was calculated from the NAAB concentration c, the reference value of kD and the measured calibration level S̃ and Ñ, via
The resulting expected photon counts were then assembled into a matrix W, such that the (i, j)th element of W is the photon count that one would have expected on the measurement of the ith NAAB if the target were the jth amino acid, given the calibration levels S̃ and Ñ. Finally, the amino acid identity Iaa was determined by minimizing the norm between the vector of observed photon counts and the columns of W, i.e., where is the kth column of W.
In Figure 4A-C, the accuracy with which amino acids can be identified is shown as a function of the observation time and the systematic error, for a 1 μM free binder concentration. In the absence of systematic error, amino acids could be identified with greater than 99% accuracy after a 50 s observation. Moreover, if the calibration error can be kept below 5%, and if the systematic error in the kinetics can be kept below 25%, then our simulations indicate that it would be possible to identify amino acids with greater than 97.5% accuracy over an observation window of 100 s.
The measurement accuracy was shown to be robust against systematic differences in brightness between different NAABs (data not shown). The experiment also showed robustness against systematic deviation in kD up to the 25% level, with progressive deterioration in the measurement accuracy observed for values of σK above 25%. Calibration error was found to have the most substantial effect on the accuracy, with calibration errors on the order of 10% reducing the achievable accuracy below 90% even for an observation time of 250 s. The effects of calibration error on the accuracy could be substantially reduced by reducing the concentration of free binders (Figure 4D), which has the effect of increasing the gap between the S and N. However, in order to preserve the requirement that Texp ≫ 1/(konc), it is necessary to increase the experiment length by a similar factor. (It is worth noting that for this reason, a free NAAB concentration of 1 μM was used, rather than 2 μM as used above.) Moreover, this improvement comes at the cost of increased sensitivity to systematic error in kD.
Application to randomized affinity matrices
In order to determine whether the protein sequencing method proposed here is limited to the specific affinity matrix given in [1], we generated affinity matrices with comparable binding statistics by randomly shuffling the kD values in the NAAB affinity matrix. For 100 such random affinity matrices, we then performed identical simulations as in fig 4E, assuming 5% calibration error and 25% kinetic error. To calculate the overall error rate for a given matrix, we summed the frequencies of incorrect residue calls (the off-diagonal elements of the matrices in fig 4E). The overall error rate for the NAAB affinity matrix, calculated in this way, is 0.0124, and the distribution of error rates across the random matrices is shown in fig 5. Only one randomly generated affinity matrix had an error rate lower than the NAAB error rate. Nonetheless, it is clear that most affinity matrices with affinity statistics similar to the NAABs [1] would yield errors in the range of 1%-4%, and thus the sequencing method described here is generalizable to a range of similar N-terminal amino acid binders.
Discussion
The calculations and simulations discussed above indicate that if the measurement apparatus can be calibrated with an accuracy of 5%, and if the reference values of kD can be kept within 25% of the true values, it is theoretically possible to determine the identity of an N-terminal amino acid with greater than 97.5% accuracy by measuring the kinetics of the NAABs against the target amino acid. Crucially, kD can be inferred just from the time-averaged local concentration of NAABs within the observation field, and thus the measurement can be performed at relatively high background binder concentrations, because it does not rely on being able to distinguish individual binding and unbinding events.
Primary Uncertainties
Three primary uncertainties exist regarding the validity of the simulations performed here. Firstly, our simulation did not incorporate the effects of non-specific binding of NAABs to the surface. Nonetheless, if such non-specific binding occurs with sufficiently low affinity, we anticipate that the effect of the non-specific binding will be comparable to the effect of increasing the affinity of the binders for the target, and we have shown that our experiment displays considerable robustness against such sources of systematic error. On the other hand, if non-specific binding occurs with high affinity, we anticipate that by examining the time-course of the luminosity, such non-specific binding events can be identified and accounted for.
In addition, some uncertainty exists surrounding the value of Nq for the organic dyes of interest to us, with values between 105 and 107 being reported [23,37]. However, we expect our method to be relatively robust to photobleaching due to the relatively low affinity and high off-rates of most of the NAABs. Moreover, it is possible that more photostable indicators such as quantum dots could be used in place of organic dyes. Note that with any labeling scheme, there will be some concentration of “dark NAABs” that are not labeled. Thus, the concentrations reported for the simulations above should be regarded as the concentrations of “bright NAABs.” The presence of dark NAABs is unlikely to affect the experimental results provided the total NAAB concentration is less than the dissociation constant (i.e., as long as the target is free most of the time), so a high concentration of dark NAABs can always be compensated for by reducing the total NAAB concentration and increasing the measurement duration.
Parallelization
We anticipate that the approaches discussed here could be parallelized in a way reminiscent of next-generation nucleic acid sequencing technologies, allowing for massively parallel protein sequencing with single-molecule resolution. In the ideal case, if a 64 megapixel camera were used with one target per pixel, we would have the ability to observe the binding kinetics of NAABs against approximately 107 protein fragments simultaneously. With an observation time of 100 seconds per amino acid-NAAB pair, this corresponds to approximately 35 minutes of observation time per amino acid, or 5 days to identify a protein fragment of 200 amino acids in length. On average, therefore, the sequencing method would have a throughput of approximately 20 proteins per second.
However, the throughput of the device could be improved dramatically if the readout mechanism were electrical, rather than optical. CMOS-compatible field-effect transistors have been developed as sensors for biological molecules [38–41]. Moreover, electrical sequencing of DNA has been accomplished using ion semiconductor sequencing [42]. Most recently, CMOS-compatible carbon nanotube FETs have been shown to detect DNA hybridization kinetics with better than 10 ms time resolution [43,44]. Similar CMOS-compatible devices have been adapted to the detection of protein concentrations via immunodetection [45]. These systems have the added benefit that they sense from a much smaller volume than TIRF does (sometimes as small as ~ 10 cubic nanometers [44]), substantially reducing the impact of noise on the measurement. A single 5 inch silicon wafer covered in transistor sensors at a density of 16 transistors per square micron would be capable of sequencing 1012 proteins simultaneously, corresponding to an average throughput of 2,000,000 proteins per second on a single wafer, or one mammalian cell every 7 minutes. Such an approach could make use of dedicated integration circuitry to compute the average NAAB occupancy at the hardware level, greatly simplifying data acquisition and processing. Moreover, if the devices were made CMOS-compatible, they could be produced in bulk, greatly improving scalability. If the intrinsic contrast provided by the NAABs is insufficient for measurements with FETs, the NAABs can be further engineered to have greater electrical contrast, for example by conjugating them on the C-terminus to an electrically salient protein such as ferritin. A combination of electrical and optical readouts may also be desirable. Recently, CMOS-compatible single-photon avalanche diode imaging systems have been developed that are capable of detecting the presence of fluorophores on a surface without magnification [46].
Finally, although the use of TIRF microscopy in the case studied here restricts the proposed approach to operate close to a reflecting surface, the use of thin sections or alternative microscopies could potentially allow such protein sequencing methods to operate in-situ inside intact cells or tissues.
Conclusion
We have shown that single molecule protein sequencing is possible using low-affinity, low-specificity binding reagents and single molecule fluorescent detection. Achieving a high-quality single molecule surface chemistry and TIRF measurement setup will be a challenge, but if this can be achieved, our results show that a wide range of binding reagent families should be adaptable to single molecule protein sequencing.
Acknowledgments
We thank Andrew Payne, Jim Havranek and Jeff Nivala for helpful discussions. SR acknowledges funding from the Fannie and John Hertz Fellowship. ESB acknowledges funding from NIH 1R01MH114031, John Doerr, Open Philanthropy, NIH 1R01EB024261, the HHMI-Simons Faculty Scholars Program, U.S. Army Research Laboratory and the U. S. Army Research Office under contract/grant number W911NF1510548, and NIH Director’s Pioneer Award 1DP1NS087724.
1.1 S1 Appendix
Due to stochasticity, noise, and context-dependence (e.g. sequence-dependence) of the NAAB-amino acid interactions, a measurement performed on the kth target will yield an approximation to the reference affinity vector . If we assume that the distribution according to which these measurements occur is Gaussian, then we can obtain a simple criterion for determining whether two N terminal amino acids will be distinguishable on the basis of affinity measurements made using a particular set of NAABs. We denote by the standard deviation of the measurements made with NAAB i against amino acid j. For each amino acid, we may define a sphere of radius ρj, centered on the vector , which surrounds that amino acid in affinity space. Here, where is the dissociation constant for the binding of the ith NAAB to the jth amino acid.
N-terminal amino acids will be identifiable with 99.9% certainty provided that there is no overlap in affinity-space between the j spheres of radius ρj. To determine whether there is such an overlap, we must consider the distance metric where the division is applied element-wise. In order to assign affinity measurements to the correct reference affinity 99.9% of the time, it is sufficient (but not necessary) to have
Using equation (27), it is then also sufficient to have
For the specific case of the NAAB affinity matrix, we find that D = 3.84. Thus, in order to ensure that the amino acids can be correctly identified 99.9% of the time, we must have or, equivalently, the standard deviation of the kD measurements must be no greater than 64% of the mean.
1.2 S2 Appendix
Under the assumption of Poissonian noise, the photon rates in the bound and unbound states are given by and respectively. In order to be able to distinguish the bound state from the unbound state, it is clear that we must have
Because λb > λf, we may replace the standard deviation on the left-hand side by the standard deviation , obtaining
Hence,
We find the final requirement:
Rephrased as a condition on the concentration of the binder, we find or
If nfree ≤ 1, then the assumption of Poissonian noise is invalidated because the emission of successive photons is not independent (it depends on the presence of fluorophores in the observation field). The assumption of Poissonian noise may also be invalidated if the frame rate is comparable to the rate at which fluorophores enter and leave the observation field. In either case, to correctly simulate the noise, one must draw the number of free binders that enter the observation field during a given frame from a Poisson distribution with mean nfreeτobs/τdwell, where τdwell is the amount of time each binder spends in the observation field on average. The average dwell time of free binders in a region of thickness Δx may be calculated as where D is the diffusion constant [23]. For a small protein in water, we have D ~ 10−10 m2 s−1. Taking Δx = 100 nm, we find that free binders will dwell on average τdwell = 100 μs within the imaging plane.
Once the number of binders entering the observation field during the frame has been determined, one must draw the length of time t that each binder remains in the frame from an exponential distribution with mean τdwell. Finally, for each binder, one must draw the number of photons emitted by that binder from a Poisson distribution with mean Rt. When the number of free binders is small, the resulting noise will differ significantly from Poisson noise due to the exponential distribution over dwell times. In our simulations, the long tail of the exponential distribution tends to significantly increase the difficulty of distinguishing transient binding and unbinding events, compared to simple Poisson noise (data not shown).
1.3 S3 Appendix
The intensity I is related to the photon rate R of the fluorophore by where h is Planck’s constant, ν is the frequency, σ is the absorption cross-section of the fluorescent dye, and R is the rate of absorption. To determine the cross-section, we note that from the Beer-Lambert law, where α is the attenuation coefficient, c is the molar concentration, and e is the molar absorptivity, which we assume is given in M−1 m−1. Furthermore, we have where σ is the absorption cross-section and n is the atomic number density. Hence, we have or, since c is the molar concentration and n is the number density, we have n = 1000NAc, where NA is Avogadro’s constant, c is given in molar and n is given in atoms per cubic meter. Thus,
Hence, the photon number is given in terms of the intensity by
1.4 S4 Appendix
One advantage of occupancy measurements is that if kon is known, then koff may be determined even in the presence of photobleaching. To do so, we note that Ti and Tb are independent variables that depend on koff, kon, and Nq. In the above analysis, we assumed that Nq was infinite, so that quenching could be neglected. If Nq is finite, however, then the true expressions for Ti and Tb are given by and
The first term in equation (48) is the average time the target spends occupied by a quenched fluorophore, while the second term is the average time the target spends unoccupied between unbinding and binding events. Hence, if kon is known, then koff and Nq may be determined from Tb and Ti.
1.5 S5 Appendix
In contrast to occupancy measurements, luminosity measurements are sensitive to error in the calibration of the measurement apparatus. Calibration error arises from a combination of systematic differences in the brightness of the on- and off-states, which may result if different NAABs have different numbers of fluorophores on average, and from systematic error in the measurement of the brightnesses of the on- and off-states. Systematic variation in the brightnesses of the fluorophores can be overcome by calibrating the device prior to each measurement (as discussed below). In general, however, systematic error in the measurement of S and N significantly disrupts attempts to determine the absolute value of kD due to divergences in the derivative of kD as M approaches N. Hence, for weak binders in particular, infinitesimal changes in the calibration level can lead to divergent changes in the measured value of kD. For this reason, if the goal of the measurement is to determine the absolute value of kD, it is essential that the concentration be chosen such that the value of M to be measured lies close to S, i.e., such that the concentration c is close to or greater than kD. If kD is large or unknown, however, this requirement may not be achievable.
In our case, however, we are interested not in determining the absolute value of kD, but rather in determining the identity of a target (N-terminal amino acid) from the binding affinities of many binders (NAABs). In this case, one may significantly reduce the effects of calibration error by using the reference values of kD to calculate the expected photon rate E from the brightnesses of the on- and off-states, for each of the possible target identities. After having performed the measurement with all 17 binders, one is left with a vector of the photon rates measured for each binder, and a set of vectors , the kth of which is the vector of photon rates that one would have expected to measure if the target were of type k. The identity of the target is then determined by minimizing the norm of over k. The key difference here is that because one compares the expected photon rates to the measured photon rates, one avoids the nonlinearities inherent in calculating the measured dissociation constant from the measured photon rate.
1.6 S6 Appendix
Figure 6 shows the full set of accuracy matrices determined by simulation for 100 random affinity matrices.