Abstract
There is described a 60-channel EEG acquisition system designed for the recording of scalp-potential distributions starting just 2.5ms after individual transcranial magnetic stimulation (TMS) pulses. The amplifier comprises gain-control and sample-and-hold circuits to prevent large artefacts from magnetically induced voltages in the leads. The maximum amplitude of the stimulus artefact during the 2.5ms gating period is 1.7 μV, and 5 ms after the TMS pulse it is only 0.9 μV. It is also shown that mechanical forces to the electrodes under the stimulator coil are a potential source of artefacts, even though, with chlorided silver wire and Ag/AgCl-pellet electrodes, the artefact is smaller than 1 μV. The TMS-compatible multichannel EEG system makes it possible to locate TMS-evoked electric activity in the brain.
Similar content being viewed by others
References
Amassian, V. E., Cracco, R. Q., Maccabee, P. J., andCracco, J. B. (1992): ‘Cerebello-frontal cortical projections in humans studied with the magnetic coil’,Electroenceph. Clin. Neurophysiol.,85, pp. 265–272
Babb, T. L., Mariani, E., Strain, G. M., Lieb, J. P., Soper, H. V. andCrandall, P. H. (1978): ‘A sample and hold amplifier system for stimulus artifact suppression’,Electroenceph. Clin. Neurophysiol.,44, pp. 528–531
Cracco, R. Q., Amassian, V. E., Maccabee, P. J., andCracco, J. B. (1989): ‘Comparison of human transcallosal responses evoked by magnetic coil and electrical stimulation’,Electroenceph. Clin. Neurophysiol.,74, pp. 417–424
EN60601-1 (1992): ‘Medical electronic equipment. Part 1: General requirements for safety’European Standard
Epstein, C. M. (1995): ‘A simple artifact-rejection preamplifier for clinical neurophysiology’,Am. J. EEG Tech.,35, pp. 64–71
Freeman, J. A. (1971): ‘An electronic stimulus artifact suppressor’,Electroenceph. Clin. Neurophysiol.,31, pp. 170–172
IEC601-2-26 (1993): ‘Medical electronic equipment-Part 2: Particular requirements for the safety of electroencephalographs’.Standard, International Electrotechnical Commission
Ilmoniemi, R. J., Virtanen, J., Ruohonen, J., Karhu, J., Aronen, H. J., Näätänen, R., andKatila, T. (1997): ‘Neuronal responses to magnetic stimulation reveal cortical reactivity and connectivity’,Neuro Report,8, pp. 3537–3540
Izumi, S.-I., Takase, M., Arita, M., Masakado, Y., Kimura, A., andChino, N. (1997): ‘Transcranial magnetic stimulation-induced changes in EEG and responses recorded from the scalp of healthy humans’,Electroenceph. Clin. Neurophysiol.,103, pp. 319–322
Jakob, C., Mathis, J., Weyh, T., andStruppler, A. (1993): ‘Artefact reduction in magnetic stimulation’,Electroenceph. Clin. Neurophysiol.,89, pp. 287–289
Kujirai, T., Sato, M., Rothwell, J. C., andCohen, L. G. (1993): ‘The effect of transcranial magnetic stimulation on median nerve somatosensory evoked potentials’,Electroenceph. Clin. Neurophysiol.,89, pp. 227–234
McGill, K., Clummins, K. L., Dorfman, L. J., Berlizot, B. B., Luet-Kemeyer, K., Nishimura, D. G., andWidrow, B. (1982): ‘On the nature and elimination of stimulus artifact in nerve signals evoked and recorded using surface electrodes’,IEEE Trans.,BME-29, pp. 129–137
MettingVanRijn, A. C., Peper, A., andGrimbergen, C. A. (1991): ‘The isolation mode rejection in bioelectric amplifiers’,IEEE Trans.,BME-38, pp. 1154–1157
Pascual-Leone, A., Houser, C. M., Reese, K., Shotland, L. I., Grafman, J., Sato, S., Valls-Solé, J., Brasil-Neto, J. P., Wassermann, E. M., Cohen, L. G., andHallett, M. (1993): ‘Safety of rapid-rate transcranial magnetic stimulation in normal volunteers’,Electroenceph. Clin. Neurophysiol.,89, pp. 120–130
Peace, R. (1983): ‘Bounding, clamping techniques improve circuit performance’,EDN Mag.,10, pp. 277–289
Rossini, P. M., Desiato, M. T., Lavoroni, F., andCaramia, M. D. (1991): ‘Brain excitability and electroencephalographic activation: non-invasive evaluation in healthy humans via transcranial magnetic stimulation’,Brain Res.,567, pp. 111–119
Roth, B. J., Pascual-Leone, A., Cohen, L. G., andHallett, M. (1992): ‘The heating of metal electrodes during rapid-rate magnetic stimulation: a possible safety hazard’,Electroenceph. Clin. Neurophysiol.,85, pp. 116–123
Seyal, M., Browne, J. K., Masuoka, L. K., andGabor, A. J. (1993): ‘Enhancement of the amplitude of somatosensory evoked potentials following magnetic pulse stimulation of the human brain’,Electroenceph. Clin. Neurophysiol.,88, pp. 20–27
Tam, H. W., andWebster, J. G. (1977): ‘Minimizing electrode motion artifact by skin abrasion’,IEEE Trans.,BME-24, pp. 134–139
Ueno, S., Tashiro, T., andHaradu, K. (1988): ‘Localized stimulation of neural tissue in the brain by means of a paired configuration of time-varying magnetic fields’,J. Appl. Phys.,64, pp. 5862–5864
Walker, D. D., andKimura, J. (1978): ‘A fast-recovery electrode amplifier for electrophysiology’,Electroenceph. Clin. Neurophysiol.,45, pp. 789–792
Virtanen, J., Rinne, T., Ilmoniemi, R. J., andNäätänen, R. (1996): ‘MEG-compatible multichannel EEG electrode array’,Electroenceph. Clin. Neurophysiol.,99, pp. 568–570
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Virtanen, J., Ruohonen, J., Näätänen, R. et al. Instrumentation for the measurement of electric brain responses to transcranial magnetic stimulation. Med. Biol. Eng. Comput. 37, 322–326 (1999). https://doi.org/10.1007/BF02513307
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02513307