Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Article
  • Published:

Skin-interfaced biosensors for advanced wireless physiological monitoring in neonatal and pediatric intensive-care units

Abstract

Standard clinical care in neonatal and pediatric intensive-care units (NICUs and PICUs, respectively) involves continuous monitoring of vital signs with hard-wired devices that adhere to the skin and, in certain instances, can involve catheter-based pressure sensors inserted into the arteries. These systems entail risks of causing iatrogenic skin injuries, complicating clinical care and impeding skin-to-skin contact between parent and child. Here we present a wireless, non-invasive technology that not only offers measurement equivalency to existing clinical standards for heart rate, respiration rate, temperature and blood oxygenation, but also provides a range of important additional features, as supported by data from pilot clinical studies in both the NICU and PICU. These new modalities include tracking movements and body orientation, quantifying the physiological benefits of skin-to-skin care, capturing acoustic signatures of cardiac activity, recording vocal biomarkers associated with tonality and temporal characteristics of crying and monitoring a reliable surrogate for systolic blood pressure. These platforms have the potential to substantially enhance the quality of neonatal and pediatric critical care.

This is a preview of subscription content, access via your institution

Access options

Rent or buy this article

Prices vary by article type

from$1.95

to$39.95

Prices may be subject to local taxes which are calculated during checkout

Fig. 1: Design and characterization of a soft, wireless chest unit for physiological monitoring of neonatal and pediatric patients.
Fig. 2: Designs for a wireless limb unit for physiological monitoring of neonatal and pediatric patients.
Fig. 3: Photographs of wireless wearable devices on neonatal and pediatric patients in the NICU and PICU, respectively, and of parental hands-on care with a healthy neonate.
Fig. 4: Representative data collected in the NICU and PICU by chest and limb units with comparisons to standard measurements.
Fig. 5: Time-synchronized operation of chest and limb units for measurements of systolic blood pressure, with comparison with arterial line data collected from pediatric patients in the PICU.
Fig. 6: Advanced monitoring modalities based on measurements of orientation, activity and vibratory motions.

Similar content being viewed by others

Data availability

All relevant data are included in the paper. Additional supporting data are available from the corresponding authors on request. All request for raw and analyzed data and materials will be reviewed by the corresponding authors to verify whether the request is subject to any intellectual property or confidentiality obligations. Patient-related data not included in the paper were generated as part of clinical trials and may be subject to patient confidentiality. Source data for Figs. 4–6 and Extended Data Figs. 2, 4, 5 and 7–10 are presented within the paper.

References

  1. Wheeler, D. S., Wong, H. R. & Shanley, T. P. Pediatric Critical Care Medicine: Basic Science and Clinical Evidence (Springer, 2007).

  2. Xu, J., Murphy, S. L., Kochanek, K. D., Bastian, B. & Arias, E. Deaths: final data for 2016. Natl. Vital Stat. Rep. 67, 1–76 (2018).

    PubMed  Google Scholar 

  3. Bonner, O., Beardsall, K., Crilly, N. & Lasenby, J. ‘There were more wires than him’: the potential for wireless patient monitoring in neonatal intensive care. BMJ Innov. 3, 12–18 (2017).

    Article  PubMed  PubMed Central  Google Scholar 

  4. Bowdle, T. A. Complications of invasive monitoring. Anesthesiol. Clin. N. A. 20, 571–588 (2002).

    Article  Google Scholar 

  5. Cilley, R. Arterial access in infants and children. Semin. Pediatr. Surg. 1, 174–180 (1992).

    CAS  PubMed  Google Scholar 

  6. Joseph, R., Chong, A., Teh, M., Wee, A. & Tan, K. Thrombotic complication of umbilical arterial catheterization and its sequelae. Ann. Avad. Med. Singapore 14, 576–582 (1985).

    CAS  Google Scholar 

  7. Baserga, M. C., Puri, A. & Sola, A. The use of topical nitroglycerin ointment to treat peripheral tissue ischemia secondary to arterial line complications in neonates. J. Perinatol. 22, 416 (2002).

    Article  PubMed  Google Scholar 

  8. Scheer, B., Perel, A. & Pfeiffer, U. J. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit. Care 6, 199–204 (2002).

    Article  PubMed  PubMed Central  Google Scholar 

  9. Chung, H. U. et al. Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care. Science 363, eaau0780 (2019).

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  10. Fanaroff, J. M. & Fanaroff, A. A. Blood pressure disorders in the neonate: hypotension and hypertension. Semin. Fetal Neonat. M. 11, 174–181 (2006).

    Article  Google Scholar 

  11. Wilson, R. A., Bamrah, V. S., Lindsay, J., Schwaiger, M. & Morganroth, J. Diagnostic accuracy of seismocardiography compared with electrocardiography for the anatomic and physiologic diagnosis of coronary artery disease during exercise testing. Am. J. Cardiol. 71, 536–545 (1993).

    Article  CAS  PubMed  Google Scholar 

  12. Mahoney, M. C. & Cohen, M. I. Effectiveness of developmental intervention in the neonatal intensive care unit: implications for neonatal physical therapy. Pediat. Phys. Ther. 17, 194–208 (2005).

    Article  Google Scholar 

  13. Shinya, Y., Kawai, M., Niwa, F., Imafuku, M. & Myowa, M. Fundamental frequency variation of neonatal spontaneous crying predicts language acquisition in preterm and term infants. Front. Psychol 8, 2195 (2017).

    Article  PubMed  PubMed Central  Google Scholar 

  14. Boundy, E. O. et al. Kangaroo mother care and neonatal outcomes: a meta-analysis. Pediatrics 137, e20152238 (2016).

    Article  PubMed Central  Google Scholar 

  15. Dehghani, K., Movahed, Z., Dehghani, H. & Nasiriani, K. A randomized controlled trial of kangaroo mother care versus conventional method on vital signs and arterial oxygen saturation rate in newborns who were hospitalized in neonatal intensive care unit. J. Clin. Neonatol 4, 26–31 (2015).

    Article  Google Scholar 

  16. Shwayder, T. & Akland, T. Neonatal skin barrier: structure, function, and disorders. Dermatol. Ther. 18, 87–103 (2005).

    Article  PubMed  Google Scholar 

  17. Mutashar, S., Hannan, M., Samad, S. & Hussain, A. Analysis and optimization of spiral circular inductive coupling link for bio-implanted applications on air and within human tissue. Sensors 14, 11522–11541 (2014).

    Article  PubMed  PubMed Central  Google Scholar 

  18. James, D. K., Dryburgh, E. H. & Chiswick, M. L. Foot length–a new and potentially useful measurement in the neonate. Arch. Dis. Child. 54, 226–230 (1979).

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  19. Means, L. W. & Walters, R. E. Sex, handedness and asymmetry of hand and foot length. Neuropsychologia 20, 715–719 (1982).

    Article  CAS  PubMed  Google Scholar 

  20. Di Rienzo, M. et al. Wearable seismocardiography: towards a beat-by-beat assessment of cardiac mechanics in ambulant subjects. Auton. Neurosci 178, 50–59 (2013).

    Article  PubMed  Google Scholar 

  21. Leeudomwong, T., Deesudchit, T. & Chinrungrueng, C. Motion-resistant pulse oximetry processing based on time-frequency analysis. Eng. J. 21, 181–196 (2017).

  22. Fu, T.-H., Liu, S.-H. & Tang, K.-T. Heart rate extraction from photoplethysmogram waveform using wavelet multi-resolution analysis. J. Med. Biol. Eng 28, 229–232 (2008).

    Google Scholar 

  23. Daw, W. et al. Medical devices for measuring respiratory rate in children: a review. J. Advs. Biomed. Eng. Techno. 3, 21–27 (2016).

    Article  Google Scholar 

  24. Bland, J. M. & Altman, D. G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327, 307–310 (1986).

    Article  Google Scholar 

  25. Lund, C. H. & Osborne, J. W. Validity and reliability of the neonatal skin condition score. J. Obstet. Gynecol. Neonatal Nurs. 33, 320–327 (2004).

    Article  PubMed  Google Scholar 

  26. Sharma, M. et al. Cuff-Less and continuous blood pressure monitoring: a methodological review. Technologies 5, 21 (2017).

    Article  Google Scholar 

  27. Payne, R. A., Symeonides, C. N., Webb, D. J. & Maxwell, S. R. Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure. J. Appl. Physiol. 100, 136–141 (2006).

    Article  CAS  PubMed  Google Scholar 

  28. Foo, J. Y. A., Lim, C. S. & Wang, P. Evaluation of blood pressure changes using vascular transit time. Physiol. Meas. 27, 685–694 (2006).

    Article  PubMed  Google Scholar 

  29. Peter, L., Noury, N. & Cerny, M. A review of methods for non-invasive and continuous blood pressure monitoring: Pulse transit time method is promising? IRBM 35, 271–282 (2014).

    Article  Google Scholar 

  30. Ma, Y. et al. Relation between blood pressure and pulse wave velocity for human arteries. Proc. Natl Acad. Sci. USA 115, 11144–11149 (2018).

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  31. Wippermann, C. F., Schranz, D. & Huth, R. G. Evaluation of the pulse wave arrival time as a marker for blood pressure changes in critically ill infants and children. J. Clin. Monit. 11, 324–328 (1995).

    Article  CAS  PubMed  Google Scholar 

  32. Galland, B. C., Tan, E. & Taylor, B. J. Pulse transit time and blood pressure changes following auditory-evoked subcortical arousal and waking of infants. Sleep 30, 891–897 (2007).

    Article  PubMed  PubMed Central  Google Scholar 

  33. World Health Organization. Kangaroo Mother Care: A Practical Guide (Department of Reproductive Health and Research, 2003).

  34. Liu, G.-Z., Guo, Y.-W., Zhu, Q.-S., Huang, B.-Y. & Wang, L. Estimation of respiration rate from three-dimensional acceleration data based on body sensor network. Telemed. J. E-Health 17, 705–711 (2011).

    Article  PubMed  PubMed Central  Google Scholar 

  35. Cattaneo, A. et al. Kangaroo mother care for low birthweight infants: a randomized controlled trial in different settings. Acta Paediatr. 87, 976–985 (1998).

    Article  CAS  PubMed  Google Scholar 

  36. Levy, J. et al. Impact of hands-on care on infant sleep in the neonatal intensive care unit. Pediatr. Pulmonol. 52, 84–90 (2017).

    Article  PubMed  Google Scholar 

  37. Reggiannini, B., Sheinkopf, S. J., Silverman, H. F., Li, X. & Lester, B. M. A flexible analysis tool for the quantitative acoustic assessment of infant cry. J. Speech Lang. Hear. Res. 56, 1416–1428 (2013).

    Article  PubMed  Google Scholar 

  38. Liu, Y. et al. Epidermal mechano-acoustic sensing electronics for cardiovascular diagnostics and human-machine interfaces. Sci. Adv. 2, e1601185 (2016).

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  39. Huntsman, R. J., Lowry, N. J. & Sankaran, K. Nonepileptic motor phenomena in the neonate. Paediatr. Child Health 13, 680–684 (2008).

    Article  PubMed  PubMed Central  Google Scholar 

  40. Fahn, S., Jankovic, J. & Hallett, M. in Principles and Practice of Movement Disorders 2nd edn (eds. Fahn, S., Jankovic, J. & Hallett, M.) Ch. 18 (W.B. Saunders, 2011).

  41. Pandia, K., Inan, O.T. & Kovacs, G.T.A. in 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) 6881–6884 (2013).

  42. Shinya, Y., Kawai, M., Niwa, F. & Myowa-Yamakoshi, M. Preterm birth is associated with an increased fundamental frequency of spontaneous crying in human infants at term-equivalent age. Biol. Lett. 10, pii: 20140350 (2014).

    Article  Google Scholar 

  43. Pickering, T. G. et al. Recommendations for blood pressure measurement in humans and experimental animals. Circulation 111, 697–716 (2005).

    Article  PubMed  Google Scholar 

  44. Brzezinski, M., Luisetti, T. & London, M. J. Radial artery cannulation: a comprehensive review of recent anatomic and physiologic investigations. Anesth. Analg. 109, 1763–1781 (2009).

    Article  PubMed  Google Scholar 

  45. Sahoo, P. K., Thakkar, H. K. & Lee, M.-Y. A cardiac early warning system with multi channel SCG and ECG monitoring for mobile health. Sensors 17, 711 (2017).

    Article  PubMed Central  Google Scholar 

  46. Inan Omer, T. et al. Novel wearable seismocardiography and machine learning algorithms can assess clinical status of heart failure patients. Circ. Heart. Fail. 11, e004313 (2018).

    CAS  PubMed  PubMed Central  Google Scholar 

  47. Hadush, M. Y., Berhe, A. H. & Medhanyie, A. A. Foot length, chest and head circumference measurements in detection of low birth weight neonates in Mekelle, Ethiopia: a hospital based cross sectional study. BMC Pediatr. 17, 111 (2017).

    Article  PubMed  PubMed Central  Google Scholar 

  48. August, D. L., New, K., Ray, R. A. & Kandasamy, Y. Frequency, location and risk factors of neonatal skin injuries from mechanical forces of pressure, friction, shear and stripping: a systematic literature review. J. Neonatal Nurs. 24, 173–180 (2018).

    Article  Google Scholar 

  49. Oranges, T., Dini, V. & Romanelli, M. Skin physiology of the neonate and infant: clinical implications. Adv. Wound Care 4, 587–595 (2015).

    Article  Google Scholar 

  50. Barbeau, D. Y. & Weiss, M. D. Sleep disturbances in newborns. Children 4, 90 (2017).

    Article  Google Scholar 

  51. Newman, J. D. Neural circuits underlying crying and cry responding in mammals. Behav. Brain Res. 182, 155–165 (2007).

    Article  PubMed  PubMed Central  Google Scholar 

  52. Corwin, M. J. et al. Newborn acoustic cry characteristics of infants subsequently dying of sudden infant death syndrome. Pediatrics 96, 73–77 (1995).

    CAS  PubMed  Google Scholar 

  53. Farsaie Alaie, H., Abou-Abbas, L. & Tadj, C. Cry-based infant pathology classification using GMMs. Speech Commun. 77, 28–52 (2016).

    Article  PubMed  PubMed Central  Google Scholar 

  54. Joshi, R. et al. A ballistographic approach for continuous and non-obtrusive monitoring of movement in neonates. IEEE J. Transl. Eng. Health Med. 6, 2700809–2700809 (2018).

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

D.E.W.-M., A.H., C.M.R., R.G. and J.A.R. acknowledge funding from the Bill & Melinda Gates Foundation (OPP1182909). S.X. and J.A.R. acknowledge additional funding from the Bill & Melinda Gates Foundation (OPP1193311). D.E.W.-M., A.H., C.M.R., R.G. and J.A.R. acknowledge support from the Gerber Foundation. A.S.P., D.E.W.-M., A.H. and J.A.R. recognize the Friends of Prentice Foundation for their support. J.A.R. and S.X. also recognize support from Save the Children (award 999002170). A.Y.R. gratefully acknowledges funding support by the National Institutes of Health’s National Center for Advancing Translational Sciences, grant TL1TR001423. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health. E.S. recognizes funding support from the WCAS Undergraduate Research Grant Program, which is administered by Northwestern University’s Weinberg College of Arts and Sciences. The conclusions, opinions and other statements in this publication are the author’s and not necessarily those of the sponsoring institution. This work is also supported by the National Natural Science Foundation of China (11402134 and 11320101001), the National Basic Research program of China (2015CB351900) and the National Science Foundation (1400159, 1534120 and 1635443). The materials and engineering efforts were supported by the Center for Bio-Integrated Electronics of the Simpson Querrey Institute at Northwestern University. This work utilized Northwestern University Micro/Nano Fabrication Facility (NUFAB), which is partially supported by Soft and Hybrid Nanotechnology Experimental (SHyNE) Resource (NSF ECCS-1542205), the Materials Research Science and Engineering Center (DMR-1720139), the State of Illinois and Northwestern University.

Author information

Authors and Affiliations

Authors

Contributions

A.S.P., S.X., D.E.W.-M., A.H., Y.H. and J.A.R. conducted the overall research program; H.U.C., A.Y.R., A.H.F., K.H.L., C.L., A.C., E.K., J.C., I.C.O., K.B.F., A.B., Jongwon Kim, H.J., M.N., J.W.K., E.S., M.A.P., R.J.K., B.V.P., K.A.H., M.P., H.S.K., S.H.L., J.D.L., Y.Y., S.R., T.S., I.J. and H.A. performed and were involved in the manufacturing of the sensors; H.U.C., A.Y.R., A.H.F., K.H.L., Z.X., C.L., D.R., E.K., J.C., W.R. and J.Y.L. were responsible for the overall engineering design of the sensors; H.U.C., A.Y.R., A.H.F., D.H.K., D.R., C.O., D.G., M.I., A.B. and J.Y.L. were responsible for data analysis; E.C.D., B.H., V.R.S., A.O., A.S., A.B., M.S., C.M.R., L.E.M., Z.L.H., A.H., A.S.P., D.E.W.-M. and S.X. were responsible for data collection; Z.X., K.H.L., R.A., Y.X. and Y.H. performed the mechanical and structural design; H.U.C., D.H.K., D.R., C.O., D.G., J.B.P., J.L., Y.P., Jungwoo Kim, H.H.J., H.H., S.S.K., M.I. and J.Y.L. performed software design, software validation, signal processing and algorithm development; A.S.P., D.E.W.-M., C.M.R., S.X. and J.A.R. were responsible for acquiring funding; H.U.C., A.R., A.H.-F., S.X., J.Y.L. and J.A.R. wrote the original draft of the manuscript; and all authors participated in editing and reviewing of the final manuscript.

Corresponding authors

Correspondence to Debra E. Weese-Mayer, Jong Yoon Lee or John A. Rogers.

Ethics declarations

Competing interests

H.U.C., S.X., D.H.K., D.R., E.K., J.C., A.B., J.B.P., J.L., J.K., H.H.J., S.S.K., J.D.L., J.Y.L. and J.A.R. declare equity ownership in a company that is pursuing commercialization of the technology described here.

Additional information

Peer review information Michael Basson was the primary editor on this article and managed its editorial process and peer review in collaboration with the rest of the editorial team.

Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Extended data

Extended Data Fig. 1 Fabrication Process of a Chest unit.

a, Leftmost and middle diagrams show the assembly process of the circuit components on a 2-layer flexible printed circuit board. Rightmost diagram shows how the sub-systems of the chest board are folded. b, The encapsulation process involves spin casting Silbione elastomer on top of a glass slide, followed by opening for the electrodes. CB PDMS is used to fill the electrode openings, then combined with the folded board that contains a battery. The top Silbione enclosure is prepared through a 2-part molding process and closes the encapsulation of the chest unit. Removing the glass slide finalizes this process. CB PDMS, carbon black in polydimethylsiloxane.

Extended Data Fig. 2 Information on connectivity, thermal safety, and modular batteries.

a, Measurement of connectivity between sensors and base station (connected with a BLE dongle) involves a received signal strength indicator (RSSI). RSSI was measured at a distance between sensors and the base station from 0 to 14 meters (incremental of 2 meters) three times at three different cases when 1) the chest unit in air, 2) the chest unit was on a healthy adult’s chest, and 3) the limb unit on the finger of the same person. Standard deviation between three measures at every distance is defined as the error bar in the plot. BLE, Bluetooth Low Energy. b, Representative pictures showing temperature changes on a subject’s chest when a chest unit is mounted, operational for 24 hours. Negligible change was observed (n = 3). c, Similarly, negligible change in temperature was observed, when a limb unit was mounted on the foot of the same subject for 24 hours in full operation (n = 3). d, Different form factors of encapsulated modular batteries. The green colored circle with the diameter of choking limit outlines the safety limits to prevent choking hazard for kids under 3 years old.

Source data

Extended Data Fig. 3 Mechanical properties of chest and limb units.

a, Schematic illustration of stack and dimension information for serpentine interconnects and sub-systems of a chest unit. PI, polyimide. Cu, copper. b, Computational result showing the stretchability and bendability of a chest unit’s board. L0, nominal length of a serpentine interconnect of the board. L*, pre-compressed length of the serpentine. ε = (L-L*)/ L* defines the elastic stretchability. c, Computational result showing the effect of thickness of the strain isolation layer regarding shear and normal stress when a chest board is assumed to be stretched by 20%. d, Schematic illustration of the stack and dimension information for serpentine interconnects of a limb unit. e, Strain distribution in the encapsulation layer (left) and copper layer (right) of an interconnect during (e) twisting, (f) stretching, (g) and bending at the radius of 3.9 mm. h, Overall bending mechanics of a limb unit board illustrated by strain distribution.

Extended Data Fig. 4 Vital signs processing algorithm.

Block diagram of the signal processing algorithm for (a) heart rate, (b) respiration rate, (c) SpO2. d,e, representative images showing differences between sub-processed time-domain and frequency-domain responses for the signal (d) without motion artifact and (e) with motion artifact. f, Block diagram of signal processing algorithm for pulse timing calculations. BPF, bandpass filter. ECG, electrocardiogram. QRS, QRS complex of ECG. R-R distance, distance between two consecutive R-peaks of ECG. ACCL, acceleration output. PPG, photoplethysmogram output. IR, infra-red.

Source data

Extended Data Fig. 5 Vital signs comparison of sensors to FDA-cleared equipment.

a, Closed view around 100 seconds of HR, SpO2, and Temperature plots in Fig. 4b. Global Bland Altman plots for b, HR (n = 515,679 from 20 NICU and PICU subjects) and c, SpO2 (n = 440,077 from 20 NICU and PICU subjects).

Source data

Extended Data Fig. 6 Time-synchronization verification experiment for the sensors.

a, Testing set up involves a signal generator sending rectangular pulses to a chest unit, while received data is streamed over to the base station. The signal generator sends a delayed signal to switch the Red LED and the photodetector in the limb unit to capture the output associated with LED switching, followed by streaming the output to the same base station. b, A representative plot showing two signals obtained from the chest and limb unit with a delay between two units defined by the signal generator. c, Mean and standard deviation of calculated timing difference compared to defined delay (testing PAT).

Extended Data Fig. 7 Analysis of estimating blood pressure using pulse timing parameters.

a, A representative plot showing large movement in accelerometry data (bottom) correlates to large and sudden changes in arterial line (A-line) derived SBP signal (top). Bland Altman plots of PAT- and PTT-derived SBP compared to A-line SBP from the data shown in b, Fig. 5d (n = 18,679 data points for both left and right), c, Fig. 5e (n = 17,449 data points for both). d, A plot (left) of A-line SBP (red) and PAT SBP (blue) and the resulting Bland Altman plot (right, n = 7,322 data points) for the subject with H/O splenectomy (39 w GA, 95 w CA). e, A plot (left) of A-line SBP (red) and PTT SBP (blue) and the resulting Bland Altman plot (right) for the same subject (n = 7,322 data points).

Source data

Extended Data Fig. 8 Analysis of estimating blood pressure using pulse timing parameters.

a, A plot (left) of A-line SBP (red) and PAT SBP (blue) and the resulting Bland Altman plot (right) for the same subject in ED Fig. 7 (n = 7,024 data points). b, A plot (left) of A-line SBP (red) and PTT SBP (blue) and the resulting Bland Altman plot (right) for the same subject in (a, n = 7,024 data points). c, A plot (left) of A-line SBP (red) and PAT SBP (blue) and the resulting Bland Altman plot (right, n = 17,514 data points) for the subject with hypoxia and hypercapnia (40 w GA, 69 w CA). d, A plot (left) of A-line SBP (red) and PTT SBP (blue) and the resulting Bland Altman plot (right) for the same subject (n = 17,514 data points). e, Accelerometry analysis to verify correlation between large spikes in A-line SBP (top) and motion artifact (bottom).

Source data

Extended Data Fig. 9 The effect of calibration window size and re-calibration period in estimating blood pressure using pulse timing parameters.

a, A plot (left) of A-line SBP vs PTT SBP obtained from the same subject in Fig. 5d and its resulting Bland Altman plot (right, n = 18,979 data points) with a single calibration was applied in the first minute of data. b, A plot (left) of A-line SBP vs PTT SBP of the same subject in (a) and its resulting Bland Altman plot (right, n = 18,739 data points) while having calibration every 30 minutes with a calibration window size of 5 minutes.

Source data

Extended Data Fig. 10 Accelerometry for analyzing characteristics of crying by a chest unit on neonates.

Representative power spectrum of signal frequency upon fast Fourier transform processing of neonatal mechano-acoustic signal during a, patting, b, resting, and c, crying. d, Bland Altman plot for comparison between cry duration calculated by a chest unit’s data and manual recording (n = 11 data points from 3 neonates).

Source data

Supplementary information

Supplementary Information

Supplementary Figs. 1–3 and Supplementary Table 1.

Reporting Summary

Supplementary Video 1

The video shows the demo of sensors operating along with the real-time streaming data to a base station, with sensors mounted on a healthy adult

Supplementary Video 2

The video shows waterproof operation of the sensors

Supplementary Video 3

The video shows real-time streaming data to a base station, when sensors were mounted on an actual pediatric patient (patient is fully de-identified)

Supplementary Video 4

The video shows the cry pattern created from the acceleration data obtained from a chest unit on a subject

Source data

Source Data Fig. 4

Statistical Source Data for Fig. 4

Source Data Fig. 5

Statistical Source Data for Fig. 5

Source Data Fig. 6

Statistical Source Data for Fig. 6

Source Data Extended Data Fig. 2

Statistical Source Data for Extended Data Fig. 2

Source Data Extended Data Fig. 4

Statistical Source Data for Extended Data Fig. 4

Source Data Extended Data Fig. 5

Statistical Source Data for Extended Data Fig. 5

Source Data Extended Data Fig. 7

Statistical Source Data for Extended Data Fig. 7

Source Data Extended Data Fig. 8

Statistical Source Data for Extended Data Fig. 8

Source Data Extended Data Fig. 9

Statistical Source Data for Extended Data Fig. 9

Source Data Extended Data Fig. 10

Statistical Source Data for Extended Data Fig. 10

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chung, H.U., Rwei, A.Y., Hourlier-Fargette, A. et al. Skin-interfaced biosensors for advanced wireless physiological monitoring in neonatal and pediatric intensive-care units. Nat Med 26, 418–429 (2020). https://doi.org/10.1038/s41591-020-0792-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/s41591-020-0792-9

This article is cited by

Search

Quick links

Nature Briefing

Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

Get the most important science stories of the day, free in your inbox. Sign up for Nature Briefing