Title: Reference values for total blood volume and cardiac output in humans

Technical Report ·
DOI:https://doi.org/10.2172/10186900· OSTI ID:10186900
 [1]
  1. Indiana Univ., South Bend, IN (United States). Division of Liberal Arts and Sciences

Much research has been devoted to measurement of total blood volume (TBV) and cardiac output (CO) in humans but not enough effort has been devoted to collection and reduction of results for the purpose of deriving typical or {open_quotes}reference{close_quotes} values. Identification of normal values for TBV and CO is needed not only for clinical evaluations but also for the development of biokinetic models for ultra-short-lived radionuclides used in nuclear medicine (Leggett and Williams 1989). The purpose of this report is to offer reference values for TBV and CO, along with estimates of the associated uncertainties that arise from intra- and inter-subject variation, errors in measurement techniques, and other sources. Reference values are derived for basal supine CO and TBV in reference adult humans, and differences associated with age, sex, body size, body position, exercise, and other circumstances are discussed.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC05-84OR21400
OSTI ID:
10186900
Report Number(s):
ORNL/TM-12814; ON: DE95000899; TRN: 94:009012
Resource Relation:
Other Information: PBD: Sep 1994
Country of Publication:
United States
Language:
English