MR-based semi-automated quantification of renal functional parameters with a two-compartment model--an interobserver analysis

Eur J Radiol. 2008 Jan;65(1):59-65. doi: 10.1016/j.ejrad.2007.10.005. Epub 2007 Nov 26.

Abstract

Purpose: To assess the interobserver agreement in a semi-automated quantification approach of MR-renal perfusion and filtration parameters with a two-compartment model analysis.

Materials and methods: Twelve consecutive patients underwent renal perfusion measurements after intravenous injection of 7 ml Gd-BOPTA at 4 ml/s at 3.0 T. Two independent observers placed two regions of interest (ROI) manually on the axial slice, one in the abdominal aorta to determine the arterial input function (AIF), and one at the tissue-air interface for retrospective triggering. The data were fitted on a pixel-by-pixel basis to the two-compartment model, producing maps of the perfusion parameters FP (plasma flow), TP (plasma mean transit time) and of the tubular filtration parameters FT (tubular flow) and TT (tubular mean transit time). A cortical ROI was segmented by selecting those pixels with plasma volume VP>10 ml/100 ml, and the model fit was repeated on a ROI basis to produce the cortical averages.

Results: The average values (observer 1/observer 2) were FP (226.2/187.3 ml/100 ml/min), TP (9.0/9.1s), FT (23.5/20.8 ml/100 ml/min), TT (142.1/140.0 s). The correlation coefficients between both observers were 0.90 (FP), 0.80 (TP), 0.80 (FT), 0.78 (TT). Correlations of all values were significant (p<0.05). A paired t-test yielded significant differences for FP (p=0.004).

Discussion/conclusion: The data demonstrate a significant systematic difference for the parameter FP, while TP seems to be most stable. Further decrease of the residual variability of all parameters seems desirable to improve the robustness of the method for clinical routine.

MeSH terms

  • Contrast Media
  • Female
  • Humans
  • Image Interpretation, Computer-Assisted
  • Kidney Diseases / diagnosis*
  • Kidney Diseases / physiopathology*
  • Magnetic Resonance Imaging / methods*
  • Male
  • Meglumine / analogs & derivatives
  • Middle Aged
  • Observer Variation
  • Organometallic Compounds
  • Prospective Studies
  • Renal Circulation

Substances

  • Contrast Media
  • Organometallic Compounds
  • gadobenic acid
  • Meglumine