User profiles for M. Komura

Makoto Komura

The University of Tokyo
Verified email at g.ecc.u-tokyo.ac.jp
Cited by 1664

Controlled fabrication of a biological vascular substitute

…, M Komura, J Berry, S Soker, G Lim, M Van Dyke… - Biomaterials, 2006 - Elsevier
Autologous and synthetic vessel grafts have been used as a vascular substitute for
cardiovascular bypass procedures. However, these materials are limited by the availability of …

DSC and TMDSC study of melting behaviour of poly (butylene succinate) and poly (ethylene succinate)

Z Qiu, M Komura, T Ikehara, T Nishi - Polymer, 2003 - Elsevier
… PBSU (M w =140,000) was supplied by Showa High Polymer Co., Ltd, and PES (M w =10,000)
used in this study was purchased from Scientific Polymer Products, Inc. (Ontario, NY). A …

Enantioselective chiral borane-mediated aldol reactions of silyl ketene acetals with aldehydes. The novel effect of the trialkysilyl group of the silyl ketene acetal on the …

…, M Komura, H Matsuo, M Nakano - The Journal of …, 1991 - ACS Publications
… One hour after the addition was completed, ether (7 mL) was added and the resulting solution
was washed with aqueous NaOH (2 x 4 mL, 2 M) and brine (3 mL). The organic phase was …

Engineering of blood vessels from acellular collagen matrices coated with human endothelial cells

GE Amiel, M Komura, OZ Shapira, JJ Yoo… - Tissue …, 2006 - liebertpub.com
Small-caliber synthetic grafts used for coronary bypass artery grafting are compromised by
thrombogenicity and accelerated intimal thickening, resulting in early graft occlusion. Herein …

The dwarf phenotype of the Arabidopsis acl5 mutant is suppressed by a mutation in an upstream ORF of a bHLH gene

A Imai, Y Hanzawa, M Komura, KT Yamamoto… - 2006 - journals.biologists.com
Loss-of-function mutants of the Arabidopsis thaliana ACAULIS 5(ACL5) gene, which
encodes spermine synthase, exhibit a severe dwarf phenotype. To elucidate the ACL5-mediated …

Improvement of data retention in HfO2/Hf 1T1R RRAM cell under low operating current

YY Chen, M Komura, R Degraeve… - 2013 IEEE …, 2013 - ieeexplore.ieee.org
One of the key concerns related to low operating current (<;50μA) of RRAM is the degraded
data retention. Most of the retention studies so far focused on high switching current range. …

Gas holdup and volumetric liquid-phase mass transfer coefficient in solid-suspended bubble columns

K Koide, A Takazawa, M Komura… - Journal of chemical …, 1984 - jstage.jst.go.jp
… This criterion of using DT3 value for columns of Z)r^0.1m is based on the observations of
sG in this work and the previous ones.9'13'16) 2.4 Correlation of kLa Akita et al.1] have …

[HTML][HTML] Antigen delivery targeted to tumor-associated macrophages overcomes tumor immune resistance

…, M Komura, S Miyano, M Goto… - The Journal of …, 2019 - Am Soc Clin Investig
Immune checkpoint inhibitors and adoptive transfer of gene-engineered T cells have emerged
as novel therapeutic modalities for hard-to-treat solid tumors; however, many patients are …

Tunable Thermal Switch via Order–Order Transition in Liquid Crystalline Block Copolymer

…, T Kaneko, Y Uematsu, H Sato-Akaba, M Komura… - Nano Letters, 2022 - ACS Publications
… the cylinder) is 0.35 W m –1 K –1 , ∼2–3 times higher than those of other BC films: 0.1 W m
–1 K –1 for h-BC (along the perpendicular direction to the cylinder) and 0.16 W m –1 K –1 for …

An animal model study for tissue-engineered trachea fabricated from a biodegradable scaffold using chondrocytes to augment repair of tracheal stenosis

M Komura, H Komura, Y Kanamori, Y Tanaka… - Journal of Pediatric …, 2008 - Elsevier
INTRODUCTION: We have designed an engineered graft fabricated from a biodegradable
scaffold using chondrocytes and applied this construct to augment repair of tracheal stenosis. …